A fix is available
APAR status
Closed as program error.
Error description
v510 OMPE customer reports that after applying the following DB2 APARs for BIF_COMPATIBILITY, the PE RECTRACE report needs to display the Incompatible function type that is found in IFCID 366 which is defined in the QW0366FN field. . PM29124 - HELP WITH HANDLING THE RELEASE INCOMPATIBLE CHAR (decimal) BUILT-IN FUNCTION ON DB2 V10 and added IFCID 366. PM48741 - SQLCODE180/SQLCODE181 AFTER MIGRATION TO DB2 V10 FOR TIMESTAMP STRING. PM66095 - HELP WITH HANDLING THE RELEASE INCOMPATIBLE CHANGE FOR VARCHAR(DECIMAL), CAST (DECIMAL AS CHAR), CAST(DECIMAL AS VARCHAR. . THE INCOMPATIBLE FUNCTION TYPE CAN BE DETERMINED BY CHECKING THE QW0366FN FIELD FOR THE FOLLOWING: . 1 - is Char(decimal) 2 - is Cast(Decimal as Char) 3 - is Timestamp Format error
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: QW0366FN field is not completely * * descripted * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: QW0366FN field is not completely descripted PROBLEM CONCLUSION: Put in report all QW0366FN values description
Problem conclusion
Put in report all QW0366FN values description KEYWORDS : QW0366FN DESCRIPTION BATCH RECORD TRACE
Temporary fix
Comments
APAR Information
APAR number
PM78041
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-11-28
Closed date
2013-02-21
Last modified date
2017-06-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK91867 UK91868
Modules/Macros
DGONF370
SH12692102 | SH12696300 |
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
21 June 2017