IBM Support

PM77681: IDISS DOESN'T USE A REUSABLE LX CAUSING PROBLEMS FOR OTHER STCS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • When Fault Analyser is shutdown following an error, LX indexes
    are consumed and not reusable.
    
    When the threshold of IEASYSxx is reached, some STCs can not
    start. An IPL is required to free them or to increase the
    threshold.
    
    Client setup for FA was in error and cause IDIS to abend.
    Automated restart software was in place, allowing IDIS to be
    restarted over and over again.
    
    But each time IDISS was started, a new LX is acquired and not
    released when the task abnormally ended. So, quickly all
    the LXs were in use and the customer had to re-IPL the system.
    

Local fix

  • Change the FA setup to prevent the IDIS abend.
    

Problem summary

Problem conclusion

Temporary fix

Comments

  • COMMENTS.1
    This APAR is a duplicate of PM74985
    

APAR Information

  • APAR number

    PM77681

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655W6900

  • Reported release

    C10

  • Status

    CLOSED DUB

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-11-25

  • Closed date

    2012-12-02

  • Last modified date

    2012-12-02

  • APAR is sysrouted FROM one or more of the following:

    PM76928

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: