PM77664: MSG0P77I INVALID STORAGE ADDRESS

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • MSG0P77I INVALID STORAGE ADDRESS may be raised when DITTO
    attempts to print diagnostics on SYSLST.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users of Ditto/ESA Version 1 Release 3   *
    *                 who have DITMOD24 loaded in the SVA.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: msg0P77I INVALID STORAGE ADDRESS may be *
    *                      raised when DITTO attempts to put out   *
    *                      diagnostics to SYSLST.                  *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF. Remove phase DITMOD24 from    *
    *                 the SVA.                                     *
    ****************************************************************
    If, during DITTO initialisation an error occurs, DITTO attempts
    to put out diagnostics to SYSLST, which results in
    msg0P77I INVALID STORAGE ADDRESS, because the SYSLST DTF
    resides in the SVA.
    

Problem conclusion

  • Phase DITMOD24 is being made non-SVA eligible.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM77664

  • Reported component name

    DITTO/ESA VSE

  • Reported component ID

    564809901

  • Reported release

    36O

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-25

  • Closed date

    2013-01-09

  • Last modified date

    2013-04-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK90849

Modules/Macros

  •    $SVADIT  DITLNK24 DITSVA   DIT0LVL
    

Fix information

  • Fixed component name

    DITTO/ESA VSE

  • Fixed component ID

    564809901

Applicable component levels

  • R36O PSY UK90849

       UP13/01/10 P E512

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Document information


More support for:

DITTO

Software version:

36O

Reference #:

PM77664

Modified date:

2013-04-23

Translate my page

Machine Translation