PM77662: DC CONFIGURATION CREATING FILES IN DMGR WSTEMP DIRECTORY AND NOT CLEANING UP

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • ITCAM 7.2 DC running on Linux
    
    We discovered after some maintenance this past weekend that when
    a JVM configured for the Data Collector (v7.2) is restarted, a
    directory is added to the Deployment Manager wstemp directory
    for the JVM and it contains a subset of information for every
    application (ear) installed in that Dmgr cell. This includes
    applications installed in JVMs that are not configured in the
    Data Collector.
    
    --
    
    We should be able to fix the code to prevent the persistence of
    
    /wstemp subdirectories of the following format:
       <node-name>.<profile-name>.<server-name>.<process-id>
    (that is the subdirectory that contains all the apps data).
    
    By 'preventing persistence', i mean that such a dir may appear
    for a
    short period of time but it will be removed almost immediately.
    

Local fix

  • na
    

Problem summary

  • Every time a WebSphere server configured with ITCAM is
    restarted, a new directory is added to WebSphere's /wstemp dir.
    
    The problem is caused by a flaw that prevented the discarding of
    unneeded /wstemp files.
    

Problem conclusion

  • The code was corrected to discard the /wstemp files as soon as
    they are not needed.
    
    The fix for this APAR is contained in 7.2.0.2 maintenance
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM77662

  • Reported component name

    ITCAM WAS DIST

  • Reported component ID

    5724L6200

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-26

  • Closed date

    2013-04-03

  • Last modified date

    2013-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITCAM WAS DIST

  • Fixed component ID

    5724L6200

Applicable component levels

  • R720 PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

Tivoli Composite Application Manager for WebSphere
ITCAM for WebSphere (Dist)

Software version:

720

Reference #:

PM77662

Modified date:

2013-04-03

Translate my page

Machine Translation

Content navigation