PM77410: DIALOG SYSTEM ABENDS WITH S0C7 CODE WHEN LEAVING OUT PART OF THE VALID FROM FIELD IN PANEL EQQAMGPP

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Dialog system abends with  S0C7 code occurs when leaving out
    part of
    the VALID FROM  field in panel EQQAMGPP.
    
    The abend can be recreated as example by the following steps:
    - Enter the dialog system via option 1.4.3 to modify an
    application In panel EQQAMGPP and leave out part of the
    VALID FROM date as follow:
    VALID FROM         ===> 12/11/      Date in the format YY/MM/DD,
    hit enter,  and the abend occurs.
    (If you blank out all it works. You get DATE MISSING, EQQA240
    EQQA240E
    Specify a valid-from date )
    After you go back in again the application is in use (EQQA103E)
    This lock will be released after awhile and you can modify the
    The problem is solid an occurs every time you leave part out
    from the
    VALID FROM data.
    The abend S0C7 does not occur only if "DD" is missing, but you
    can
    get the same problem also in case "YY" is missing, or also in
    case
    2 of the date values (any 2 ) are missing.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All TWSz users, updating panel EQQAMGPP.     *
    *                 FUNCTION=DIALOG                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: ISPF Dialog ABENDs S0C7 when EQQAMGPP   *
    *                      contains an incomplete VALID FROM       *
    *                      field.                                  *
    ****************************************************************
    * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR               *
    ****************************************************************
    When setting partially the VALID FROM field (YY/MM/DD) on
    panel EQQAMGPP, an abend S0C7 occurs due to a wrong date
    processing. For example VALID FROM ===> 12/11/
    where DD (day value) is missing.
    A minor problem has also been fixed. A trace message was
    issued in the MLOG when Browsing a view of the plan:
    "EQQZ024I GSVIE new selp".
    

Problem conclusion

  • Code and panel EQQAMGPP have been modified to properly
    detect the missing value (year, month, day) in the
    VALID FROM field.
    The trace wrongly left in the base code of TWS 8.5.1
    has been prevented from being always issued to MLOG.
    3A1Y
    3A2Y
    3A3Y
    3A4Y
    302Y
    5A1Y
    5A2Y
    5A3Y
    5A4Y
    5E1Y
    5E2Y
    5E3Y
    5E4Y
    502Y
    512Y
    6A1Y
    6A2Y
    6A3Y
    6A4Y
    6A5Y
    602Y
    EQQAMGPP
    EQQGSVIE
    EQQXI2OX
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM77410

  • Reported component name

    TIV WRKLD SCHD

  • Reported component ID

    5697WSZ01

  • Reported release

    602

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-20

  • Closed date

    2012-12-06

  • Last modified date

    2013-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK90102 UK90103 UK90104 UK90105 UK90106 UK90107 UK90108 UK90109
    UK90110 UK90111 UK90112 UK90113 UK90114 UK90115 UK90116 UK90117
    UK90118 UK90119 UK90120 UK90121 UK90122

Modules/Macros

  • EQQAMGPP EQQGSVIE EQQXI2OX
    

Fix information

  • Fixed component name

    TIV WRKLD SCHD

  • Fixed component ID

    5697WSZ01

Applicable component levels

  • R3A1 PSY UK90102

       UP13/02/09 P F302

  • R3A2 PSY UK90103

       UP13/02/09 P F302

  • R3A3 PSY UK90104

       UP13/02/09 P F302

  • R3A4 PSY UK90105

       UP13/02/09 P F302

  • R302 PSY UK90106

       UP13/02/09 P F302

  • R5A1 PSY UK90107

       UP13/02/09 P F302

  • R5A2 PSY UK90108

       UP13/02/09 P F302

  • R5A3 PSY UK90109

       UP13/02/09 P F302

  • R5A4 PSY UK90110

       UP13/02/09 P F302

  • R5E1 PSY UK90111

       UP13/02/09 P F302

  • R5E2 PSY UK90112

       UP13/02/09 P F302

  • R5E3 PSY UK90113

       UP13/02/09 P F302

  • R5E4 PSY UK90114

       UP13/02/09 P F302

  • R502 PSY UK90115

       UP13/02/09 P F302

  • R512 PSY UK90116

       UP13/02/09 P F302

  • R6A1 PSY UK90117

       UP13/02/09 P F302

  • R6A2 PSY UK90118

       UP13/02/09 P F302

  • R6A3 PSY UK90119

       UP13/02/09 P F302

  • R6A4 PSY UK90120

       UP13/02/09 P F302

  • R6A5 PSY UK90121

       UP13/02/09 P F302

  • R602 PSY UK90122

       UP13/02/09 P F302

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

z/OS family

Software version:

602

Reference #:

PM77410

Modified date:

2013-03-04

Translate my page

Machine Translation

Content navigation