Error description

  • Our 3.1 CMAS reached a short on storage condition DFHSM0133
    and did not recover, so was cancelled.
    There was a batch job (EFGJOBB) running at the time of the issue
    (to refresh our production proving environment in CPSM).
    This job was cancelled as well but on CMAS restart we ran
    into multiple errors:
    09.38.57 STC23720  +EYUXD0806E CMASABDC API ESSS Connection has
    failed. ESSS Response (6)
    
    09.38.57 STC23720  +EYUXD0804E CMASABCD Connection task unable
    to recover from failure(s).  Task being terminated
    EYUXL0905E CMASQABCD ASRA IN XCLD, OFFSET 000005E4
    09.38.57 STC23720  +EYUXL0112E CMASABCD CMAS initialization
    failed
    
    
    09.38.57 STC23720  +DFHDU0201 CMASABCD ABOUT TO TAKE SDUMP.
    DUMPCODE: EYUXL001, DUMPID: 27/0003
    .
    The subsequent CMAS restart failed with :
    EYUXC0006S CMASABCD Unable to create Data Cache Management
    Dataspace, DSPSERV RC=00000008, REAS=6B000911
    and many dumps issued by ESSS :
    Dump Title: CICSPlex SM 310  Lock Management Abend,SSRCVLOCK
    ,CMASABCD,LPAR,10/23/12,09:40:26
    .
    DSPSERV RC=00000008, REAS=6B000911 codes mean that
    the DMDS dataspace create attempt has failed since the name
    is not unique, already exists.
    Running IPCS RSMDATA DPSACE command on the dump gives a list
    of the dataspaces owned by the ESSS and shows they they all
    exist but are orphaned and the CMAS restart attempts fail.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V4R1M0 and V4R2M0 Users      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Unpredicatble results may occur if a    *
    *                      CMAS that was active is restarted at    *
    *                      the same time that the last MAS or      *
    *                      batch API program that was connected to *
    *                      the CMAS when it was originally active  *
    *                      is being terminated.                    *
    *                                                              *
    *                      Results that may occur include but are  *
    *                      not limited to the following:           *
    *                                                              *
    *                      -  CMAS initialization may fail after   *
    *                         receiving messages EYUXD0806E and    *
    *                         EYUXD0804E:                          *
    *                                                              *
    *                           EYUXD0806E API ESSS Connection has *
    *                                      failed. ESSS Response   *
    *                                      (6)                     *
    *                                                              *
    *                           EYUXD0804E Connection task unable  *
    *                                      to recover from         *
    *                                      failure(s).  Task being *
    *                                      terminated              *
    *                                                              *
    *                      -  CMAS initialization may fail after   *
    *                         receiving messages EYUXC0006S and    *
    *                         EYUXC0002E:                          *
    *                                                              *
    *                           EYUXC0006S Unable to create Data   *
    *                                      Cache Management        *
    *                                      Dataspace, DSPSERV      *
    *                                      RC=00000008,            *
    *                                      REAS=6B000911           *
    *                                                              *
    *                           EYUXC0002E Data Cache              *
    *                                      initialization failed   *
    *                                                              *
    *                      -  System dumps may be taken on behalf  *
    *                         of the CPSM Lock Management PC       *
    *                         routines for various CPSM regions on *
    *                         the LPAR.  The dump title of these   *
    *                         abends will be similar to the        *
    *                         following:                           *
    *                                                              *
    *                           CICSPlex SM <cpsmversion>  Lock    *
    *                           Management Abend,<routine>,        *
    *                           <jobname>,<lparid>,<date>,<time>   *
    *                                                              *
    *                      Note that the failure to restart the    *
    *                      CMAS on the LPAR and the abends will    *
    *                      occur until the LPAR is IPLed or the    *
    *                      CPSM ESSS is terminated through the     *
    *                      EYU9XEUT utility.  Note also that if    *
    *                      the EYU9XEUT utility is used to         *
    *                      terminate the ESSS, most likely the     *
    *                      FORCE option will be required.          *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, the CPSM ESSS (Environment Service     *
    *                 System Services) subsystem address space     *
    *                 (EYUXvrm, where vrm=410 for CPSM V4R1M0 or   *
    *                 vrm=420 for CPSM V4R2M0) must be terminated  *
    *                 on every MVS image where a CMAS has          *
    *                 executed, since the last IPL.                *
    *                                                              *
    *                 This can be accomplished in either of two    *
    *                 ways:                                        *
    *                                                              *
    *                   1 - IPL the MVS Image.                     *
    *                                                              *
    *                 Or:                                          *
    *                                                              *
    *                   2 - Stop all CMASes and MASes on an MVS    *
    *                       image.                                 *
    *                                                              *
    *                     - Use EYU9XENF to check that no address  *
    *                       spaces are connected to the ESSS       *
    *                       subsystem.                             *
    *                                                              *
    *                     - Use the EYU9XEUT TERMINATE function to *
    *                       stop the ESSS.                         *
    *                                                              *
    *                     - Refresh LLA to ensure the updated      *
    *                       version of EYU9Xvrm is picked up.      *
    *                                                              *
    *                     - Restart any CMASes and MASes which     *
    *                       execute on the MVS image, insuring     *
    *                       that updated libraries are being       *
    *                       picked up.  When the first CMAS is     *
    *                       started the EYUXvrm address space will *
    *                       be started automatically.              *
    *                                                              *
    *                 For details on EYU9XENF and the EYU9XEUT     *
    *                 TERMINATE function refer to "CICS            *
    *                 Transaction Server for z/OS CICSPlex SM      *
    *                 Problem Determination Version 4 Release 1"   *
    *                 (GC34-7037-xx) or "CICS Transaction Server   *
    *                 for z/OS CICSPlex SM Problem Determination   *
    *                 Version 4 Release 2" (GC34-7203-xx).         *
    *                                                              *
    *                 Note that each MVS image can be updated      *
    *                 separately, and systems on an MVS image that *
    *                 are using the new code can communicate with  *
    *                 systems on other MVS images that are not yet *
    *                 using the new code.                          *
    ****************************************************************
    When a CMAS first comes up on an LPAR, a connected address space
    element (CASTE) is allocated for the CMAS, activated and placed
    in the active CMAS chain.  Additionally, private (COMx, MONx,
    RTAx, BASx) and shared (DMDS, DATx, QUEx, TOPx, WLMx, MASx)
    dataspaces are allocated for the CMAS.
    
    When the CMAS terminates while no MASes or batch API programs
    are connected to it, its CASTE is deactivated, removed from the
    active CMAS chain and deallocated, and the private and shared
    dataspaces are deleted.
    
    When the CMAS terminates while at least one MAS or batch API
    program is connected to it, its CASTE is deactivated but remains
    allocated and on the active CMAS chain, the private dataspaces
    are deleted, and the shared dataspaces remain allocated.
    
    If the CMAS restarts before all the connected MASes and batch
    API programs terminate, then the CMAS CASTE is reactivated, the
    shared dataspaces remain allocated, and the private dataspaces
    are allocated.
    
    If all connected MASes and batch API programs terminate before
    the CMAS is restarted, then when the last of these terminate the
    CMAS CASTE is removed from the active CMAS chain and deallocated
    and the shared dataspaces are deleted.
    
    If the CMAS restarts after all the connected MASes and batch API
    programs terminate, then a new CASTE is allocated for the CMAS,
    activated and placed in the active CMAS chain, and the private
    and shared dataspaces are allocated for the CMAS.
    
    A problem can occur if the last MAS or batch API program
    terminates at the same time the CMAS is restarted.  In this
    situation, if the termination request is processed first, a
    serialization error can allow the termination of the MAS or
    batch API program to trigger the remove of the CMAS's CASTE from
    the active CMAS chain and deallocate it, and delete the shared
    dataspaces, at the same time as the start up of the CMAS
    triggers the reuse and reactivation of the CASTE and the reuse
    of the shared dataspaces.  If this occurs, the symptoms noted
    above will occur.
    

Problem conclusion

  • A number of updates have been made to ensure that the
    serialization error is addressed:
    
    -  Copybook EYURXECA, which defines the CASTE, has been updated
       to add a new status flag, CAST_CSTA_DEAD, which is set when a
       CMAS's CASTE is being deallocated.
    
    -  Copybook EYURXEES, which defines the parameter list for the
       ESSS connect process, has been updated to return to new
       status of XEES_CMASDEAD when a CMAS attempts to connect to
       the ESSS at the same time that a termination of a MAS or
       batch API program has resulted in the CASTE being deallocated
       for the CMAS.
    
    -  Method EYU0XLBV (XLBV), which issues the ESSS connect request
       during CMAS initialization, has been updated to recognize if
       a connect request returns the new XEES_CMASDEAD status.  If
       so, XLBV will delay for one second and retry the connect
       request.  XLBV will do this for up to 10 retries.
    
    -  Copybook EYU2XEEC, which is included in the PC routines
       program EYUTXEPC and processes the ESSS connect request, has
       been updated to check for a CASTE status of CAST_CSTA_DEAD
       when processing a CMAS connect request when the CASTE already
       exists.  If this status is found, the connect is failed with
       the new XEES_CMASDEAD status.
    
    -  Copybook EYU2XERT, which is included in the PC routines
       program EYUTXEPC and processes the deallocation of a CMAS's
       CASTE and the deleting of the shared dataspaces, has been
       updated to set the CMAS's CASTE status to CAST_CSTA_DEAD
       before starting the deallocation and deletion.
    

Temporary fix

  •             *********
                * HIPER *
                *********
    FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM77204

  • Reported component name

    CICS TS Z/OS V4

  • Reported component ID

    5655S9700

  • Reported release

    60M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-15

  • Closed date

    2012-12-10

  • Last modified date

    2013-01-02

  • APAR is sysrouted FROM one or more of the following:

    PM77186

  • APAR is sysrouted TO one or more of the following:

    PM78547 UK90189 UK90190

Modules/Macros

  •    EYUTXEPC EYU0XLBV EYU9X410 EYU9X420
    

Fix information

  • Fixed component name

    CICS TS Z/OS V4

  • Fixed component ID

    5655S9700

Applicable component levels

  • R60M PSY UK90189

       UP12/12/13 P F212

  • R70M PSY UK90190

       UP12/12/13 P F212

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: