PM77164: CCL9126E Required message queue (key 0xnnnnnnnn) already exists, will not reuse is written to the CICS Client log.

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Messages like the following are written to the CICS Client log
    when running CICS TG for Linux on POWER:
    [9300] TRN:CCL9126E Required message queue (key 0xD06F0003)
                        already exists, will not reuse
    [7216] API:CCL1048E Error in function 'FaarqStart'(Error Code =
                                                                 -3)
    [7263] API:CCL1048E Error in function 'CreateAServicethread'
                                                    (Error Code = 4)
    [7090] API:CCL1048E Error in function 'CreateEciEpiThread'
                                                    (Error Code = 4)
    
    Additional search words: msgCCL9126 CCL9126 msgCCL9126E
    msgCCL1048 CCL1048 msgCCL1048E
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of CICS TG for Linux on POWER.
    ****************************************************************
    PROBLEM SUMMARY:
    PROBLEM SUMMARY:
    ****************************************************************
    

Problem conclusion

  • CICS TG has been changed so that when the client application
    <br/>terminates, CICS TG deletes the IPC queue used by the
    client <br/>application to communicate with the client daemon.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM77164

  • Reported component name

    CICS TRNS GATE

  • Reported component ID

    5724I8101

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-15

  • Closed date

    2012-12-05

  • Last modified date

    2013-07-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS TRNS GATE

  • Fixed component ID

    5724I8101

Applicable component levels

  • R720 PSY

       UP