IBM Support

PM73551: CQ Web 8.0.0.x does not recognize a modified drop down list control field if it was originally set via hook

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CQ Web 8.0.0.x does not recognize a modified drop down list
    control field if it was originally set via hook
    
    Steps to reproduce
    
    1.)  Add a hook to list control named 'Email_sent' on a CQ
    record that resets the value from Yes to No using
    $entity-?SetFieldValue( 'Email_sent', 'No' );
    
    2.)  Modify the record and change 'Email_sent' to Yes.
    
    3.)  Select a notes field on the record and add some text.
    Email_sent will be reset to No by the hook
    
    4.)  Go back to 'Email_sent' and change it to Yes.
    
    5.)  Commit the record
    
    CQ Web 8.0.0.x does not recognize that Email_sent was set to Yes
    so the e-mail is not sent.  This was not a problem in CQ Web
    7.1.2.x.
    

Local fix

Problem summary

  • If a drop down list control field was reset via hook and then is
     modified, CQ Web 8.0.0.x can not recognize the modified field
    and treats it as unchanged.  NOTE - This issue only occurs in CQ
     Web 8.0.0.x.
    

Problem conclusion

  • A fix is available in ClearQuest 8.0.0.5.
    
    CQ Web now correctly recognizes a modified drop down list
    control field if it was originally set via hook
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM73551

  • Reported component name

    CLEARQUEST WIN

  • Reported component ID

    5724G3600

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-09-24

  • Closed date

    2013-02-08

  • Last modified date

    2013-02-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARQUEST WIN

  • Fixed component ID

    5724G3600

Applicable component levels

  • R710 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSH5A","label":"Rational ClearQuest"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
08 February 2013