PM73495: ECI_ERR_INVALID_DATA_LENGTH is returned when flowing a 32767 byt e COMMAREA to IPIC connected CICS servers.


Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When an ECI request with a 32767 byte COMMAREA is sent to an
    IPIC connected CICS server, return code -1
    ECI_ERR_INVALID_DATA_LENGTH is received.
    

Local fix

  • Use 32766 byte COMMAREAs or IPIC channels and containers
    support.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of CICS Transaction Gateway and IPIC connected CICS
    servers.
    ****************************************************************
    PROBLEM SUMMARY:
    When sending ECI requests to IPIC connected CICS servers, CICS
    TG was incorrectly restricting the maximum COMMAREA length to
    32766 bytes. The maximum usable size of a COMMAREA when using
    the IPIC protocol is 32767 bytes.
    ****************************************************************
    

Problem conclusion

  • CICS TG has been changed to allow a maximum COMMAREA length of
    32767 bytes to be flowed over IPIC connections. ECI requests
    specifying COMMAREAs longer than 32767 bytes will continue to
    receive ECI_ERR_INVALID_DATA_LENGTH. This change does not
    affect non-IPIC protocols.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM73495

  • Reported component name

    CICS TRNS GATE

  • Reported component ID

    5724I8102

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-09-24

  • Closed date

    2012-10-05

  • Last modified date

    2012-10-05

  • APAR is sysrouted FROM one or more of the following:

    PM69924

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS TRNS GATE

  • Fixed component ID

    5724I8102

Applicable component levels

  • R800 PSY

       UP

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

CICS Transaction Gateway

CTG


Software version:
8.0


Reference #:
PM73495


Modified date:
2012-10-05

Translate my page

Content navigation