IBM Support

PM73495: ECI_ERR_INVALID_DATA_LENGTH is returned when flowing a 32767 byte COMMAREA to IPIC connected CICS servers.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When an ECI request with a 32767 byte COMMAREA is sent to an
    IPIC connected CICS server, return code -1
    ECI_ERR_INVALID_DATA_LENGTH is received.
    

Local fix

  • Use 32766 byte COMMAREAs or IPIC channels and containers
    support.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of CICS Transaction Gateway and IPIC connected CICS
    servers.
    ****************************************************************
    PROBLEM SUMMARY:
    When sending ECI requests to IPIC connected CICS servers, CICS
    TG was incorrectly restricting the maximum COMMAREA length to
    32766 bytes. The maximum usable size of a COMMAREA when using
    the IPIC protocol is 32767 bytes.
    ****************************************************************
    

Problem conclusion

  • CICS TG has been changed to allow a maximum COMMAREA length of
    32767 bytes to be flowed over IPIC connections. ECI requests
    specifying COMMAREAs longer than 32767 bytes will continue to
    receive ECI_ERR_INVALID_DATA_LENGTH. This change does not
    affect non-IPIC protocols.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM73495

  • Reported component name

    CICS TRNS GATE

  • Reported component ID

    5724I8102

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-09-24

  • Closed date

    2012-10-05

  • Last modified date

    2012-10-05

  • APAR is sysrouted FROM one or more of the following:

    PM69924

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS TRNS GATE

  • Fixed component ID

    5724I8102

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMJ2","label":"CICS Transaction Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: