A fix is available
APAR status
Closed as new function.
Error description
Program Interface sample program SEQQSAMP(EQQPIFJV) as currently supplied stops processing if the last variable defined in a new table is DEPENDENT. The program source will be updated to add a check for a NEWTABLE statement before terminating. This will make it possible to create multiple tables in a single session when one or more of the new tables ends with a DEPENDENT variable.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All TWS for zOS users running EQQPIFJV * * sample. * * FUNCTION=SAMP * **************************************************************** * PROBLEM DESCRIPTION: Error in EQQPIFJV when defining more * * JCL Variable Tables at one time. * **************************************************************** * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR * **************************************************************** When running EQQPIFJV to define more Variable Tables at one time, any ADDTABLE statement following a preceeding table definion might fail if the last variable defined in the previous table is a Dependent variable. The ADDTABLE statement is ignored and the EQQPIFJV processing stops.
Problem conclusion
Temporary fix
Comments
The problem only occurs when the code to handle the definition of a dependent variable is invoked and the next statement to be processed is a following ADDTABLE. ADDTABLE was not included among the valid statements.
APAR Information
APAR number
PM72971
Reported component name
TIV WRKLD SCHD
Reported component ID
5697WSZ01
Reported release
602
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-14
Closed date
2012-10-05
Last modified date
2012-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK82391 UK82392 UK82393 UK82394
Modules/Macros
EQQPIFJV
Fix information
Fixed component name
TIV WRKLD SCHD
Fixed component ID
5697WSZ01
Applicable component levels
R300 PSY UK82391
UP12/11/17 P F211
R500 PSY UK82392
UP12/11/17 P F211
R510 PSY UK82393
UP12/11/17 P F211
R600 PSY UK82394
UP12/11/17 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.