Error description
Client scans PL/I code but instead of normal completion, they receive a DMH1817E message indicating there are multiple entry points for a particular module, and the Run Unit for that module is not resolved.
Local fix
none known
Problem summary
References to alternate Entry points were not being resolved within the Compile unit before searching for resolution outside the Compile unit, thereby leading to the existence of multiple Entry points per Site. The issue is more pronounced for PL/I and Assembler programs.
Problem conclusion
Subroutine entry point resolution has been changed. The Container, Application and Site of the calling Program are now taken into consideration when resolving the location of the called Program.
Temporary fix
Comments
APAR Information
APAR number
PM72745
Reported component name
RAA FOR SSTEM Z
Reported component ID
5655W5700
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-12
Closed date
2012-11-13
Last modified date
2012-11-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DMH0731 rureso
Fix information
Fixed component name
RAA FOR SSTEM Z
Fixed component ID
5655W5700
Applicable component levels
R600 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.