A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 S0C4 occurs on panel EQQALSEP with ADVANCED PANELS set to YES and all panel fields except OP EXTENDED JOBNAME left blank. If all fields other than OP EXTENDED JOBNAME are blank, and any value is entered in the OP EXTENDED JOBNAME, the abend the abend occurs when the enter key is pressed. . IRX0250E System abend code 0C4, reason code 00000016 IRX0255E Abend in host command SELECT or address environment routine ISPEXEC System abend code =0C4 Reason code =10 Module name . . . :EQQXINIX
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All TWS for zOS 8.6.0 users running with * * Advanced ISPF dialog option set to Y. * * FUNCTION=DIALOG * **************************************************************** * PROBLEM DESCRIPTION: If filtering on panel EQQALSEP (1.4.3) * * by using any value in OP EXTENDED * * JOBNAME an ISPF ABEND 0C4 occurs. * **************************************************************** * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR * **************************************************************** ABEND0C4 S0C4 occurs on panel EQQALSEP with ADVANCED PANELS set to YES. If all fields other than OP EXTENDED JOBNAME are left to blank, and any value is entered in the OP EXTENDED JOBNAME, the abend S0C4 occurs when the enter key is pressed.
Problem conclusion
Pointer values were used to evaluate an offset inside the Operation Extended Information section. In case of missing sections, the pointer value can be outside the AD record owned area, causing the ABEND. 602Y EQQALADX
Temporary fix
Comments
APAR Information
APAR number
PM72732
Reported component name
TIV WRKLD SCHD
Reported component ID
5697WSZ01
Reported release
602
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-12
Closed date
2012-09-24
Last modified date
2012-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK82037
Modules/Macros
EQQALADX
Fix information
Fixed component name
TIV WRKLD SCHD
Fixed component ID
5697WSZ01
Applicable component levels
R602 PSY UK82037
UP12/11/17 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.