PM71344: ABEND0C4 IN DGADTLS1+52E2 AFTER SITA166I MESSAGE.

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • ABEND0C4 abend in DGADTLS1+52E2 after SITA166I message.
    
    If C:D z/OS 5.1.1 is timed out by the Operating System after a
    SITA166I message, then instead of the normal ABEND322 there is
    an ABEND0C4 in DGADTLS1+52E2.
    

Local fix

  • STRRTC - 344300
    RS / RS
    
    Circumvention:
    Run with TIME=1440.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Sterling Connect:Direct V5.1.x  *
    ****************************************************************
    * PROBLEM DESCRIPTION: S0C4 ABEND IN DGADTLS1+52E2 AFTER       *
    *                      SITA166I MESSAGE.                       *
    ****************************************************************
    * RECOMMENDATION: Apply this maintenance.                      *
    ****************************************************************
    S0C4 ABEND IN DGADTLS1+52E2 AFTER SITA166I MESSAGE.
    

Problem conclusion

  • S0C4 ABEND IN DGADTLS1+52E2 AFTER SITA166I MESSAGE.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM71344

  • Reported component name

    STR CD FOR Z/OS

  • Reported component ID

    5655X0100

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-08-22

  • Closed date

    2012-10-16

  • Last modified date

    2012-12-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK82658

Modules/Macros

  • DGADTLS1 DGASSLSG DGA71344
    

Fix information

  • Fixed component name

    STR CD FOR Z/OS

  • Fixed component ID

    5655X0100

Applicable component levels

  • R510 PSY UK82658

       UP12/10/17 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page: