APAR status
Closed as program error.
Error description
When deleting some sub types within a type tree, any group object that refers to those sub-types could potentially become truncated. Were you to drag in or copy, from another type tree, the same sub-types that were just deleted, the type tree would still be incomplete and analysis errors would occur.
Local fix
WTXCQ - WTX00041262 PB / PB Circumvention: Export the type tree, and delete the required sub-types from the resulting .MTS file, and then re-import.
Problem summary
Users Affected: WebSphere Transformation Extender Design Studio users Problem Description: Design Studio truncates the component names of the types listed in the component window if the component types are deleted in the type tree. Platforms Affected: Windows
Problem conclusion
Fixed a problem with Design Studio where it does not truncate the component names of a type if the component type is deleted from the type tree. Delivered in: 8.1.0.6, 8.2.0.7, 8.3.0.5, 8.4.0.4
Temporary fix
Comments
APAR Information
APAR number
PM71164
Reported component name
WEBSPHERE DESIG
Reported component ID
5724M4008
Reported release
840
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-08-20
Closed date
2012-09-14
Last modified date
2013-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE DESIG
Fixed component ID
5724M4008
Applicable component levels
R810 PSY
UP
R820 PSY
UP
R830 PSY
UP
R840 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.