IBM Support

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 11 users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. Connections column in MRO           *
    *                          Conversations panel display cannot  *
    *                          be sorted.                          *
    *                          APAR PM72791                        *
    *                      02. IDIUTIL LISTHF report shows blank   *
    *                          abend code for CICS dump code       *
    *                          fault entries.                      *
    *                          APAR PM70382                        *
    *                      03. IDILANGX fails to process a PL/I    *
    *                          struct if its name is used for a    *
    *                          struct member elsewhere. (Problem   *
    *                          only occurs when the member name    *
    *                          is declared first).                 *
    *                          APAR PM68795                        *
    *                      04. IDILANGX does not recognize         *
    *                          'Object-Ref' types in data division *
    *                          map section.                        *
    *                          APAR PM72795                        *
    *                      05. Fault Analyzer Recovery Fault       *
    *                          Recording process might fail with   *
    *                          IDI0011S message.                   *
    *                          APAR PM72807                        *
    *                      06. IDI0092S Time 2 minutes for         *
    *                          analysis exceeded.                  *
    *                          APAR PM70634                        *
    *                      07. EUDSA PAM display incorrect.        *
    *                          APAR PM72794                        *
    *                      08. Message IDI0115E and IDI0120S due   *
    *                          to abend S002 in Fault Analyzer.    *
    *                          Possibly also message IEC036        *
    *                          002-18.                             *
    *                          APAR PM71543                        *
    *                      09. Abend S0C9 at entry point           *
    *                          displayISPF statement 3782 offset   *
    *                          X'1CE1A' during MVS dump analysis.  *
    *                          APAR PM72653                        *
    *                      10. ABEND0C4-4 in DUBBEDER at offset    *
    *                          X'D4' when Fault Analyzer called    *
    *                          for an abend in a TCB not running   *
    *                          in key 8.                           *
    *                          APAR PM72787                        *
    *                      11. IDILANGX ends with rc=310 when      *
    *                          processing VS COBOL II Rel 2.0      *
    *                          compile listing.                    *
    *                          APAR PM72088                        *
    *                      12. IDILANGX 0C4 in LINE_TO_STMT()      *
    *                          when processing OS VS/COBOL         *
    *                          compiler listing.                   *
    *                          APAR PM72087                        *
    *                      13. IDILANGX of HLASM SYSADATA gets     *
    *                          RC=0310.                            *
    *                          APAR PM69665                        *
    *                      14. Fault Analyzer problem report notes *
    *                          a recovered LE event as the point   *
    *                          of failure.                         *
    *                          APAR PM73774                        *
    *                      15. IDI0034I Fault analysis skipped due *
    *                          to: Abend S0C4 and SVC dump with    *
    *                          title COMPON=JES3 ALLOCATION,       *
    *                          COMPID=SC1BA, ISSUER=IATSIAI-RELENQ *
    *                          APAR PM74207                        *
    *                      16. Abend S0C4 in FindSymAddr when      *
    *                          processing Enterprise PL/I          *
    *                          parameter variables.                *
    *                          APAR PM73984                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    01. The column definition was incorrect.
    02. Support for CICS dump codes was missing.
    03. IDILANGX fails to create a symbol for the struct.
    04. 'Object-Ref' not recognized.
    05. The RFR dump process might get a secondary 0C4 abend in
        IDIXALG offset X'5B2' with R9 address invalid.
    06. A loop occurred during scanning of storage for an
        eyecatcher due to an incorrect address parameter.
    07. The incorrect page size was being used when building the PAM
        display.
    08. A fault entry EX segment length exceeded the history file
        LRECL of 10000 bytes.
    09. A value had not been initialized.
    10. If a TCB not running in key 8 abends, and Fault analyzer is
        called, a secondary 0C4 can occur in DUBBEDER causing an
        SVC dump with title TITLE=ABDUMP ERROR,COMPON=ABDUMP,
        COMPID=5752-SCDMP,ISSUER=IEAVTABD.
    11. IDILANGX does not support VS COBOL II Rel 2.0.
    12. Line_Acc_Info overlayed following multiple valid_info
        entries.
    13. IDISF8231S Missing ENTRY ESD information. IDISF8233S Unable
        to determine identity of unnamed PC section. RC=0310 when
        the assembly uses an unnamed CSECT or START statement.
    14. When an LE condition occurs, and is recovered from, then
        Fault Analyzer might incorrectly report the event that was
        recovered as the point of failure.
    15. Following invocation for a S1FB abend, an abend S0C4
        occurred in load module IATSIAI offset X'182' during
        dynamic allocation for a C run-time fopen() call. The cause
        of the problem being that Fault Analyzer was invoked during
        unconditional logoff processing for a TSO user.
    16. Parameter storage accessibility not checked.
    

Problem conclusion

  • 01. The column definition has been corrected.
    02. Support for CICS dump codes has been added.
    03. IDILANGX now creates a new symbol for the struct.
    04. 'Object-Ref' now recognized and resolved to pointer type.
    05. R9 setup is corrected.
    06. The incorrect address parameter has been corrected.
    07. Code has been added to dynamically check which page size to
        use.
    08. EX segments exceeding 10000 bytes have been split into
        multiple shorter segments.
    09. The required value has now been initialized.
    10. The DUBBEDER code has been changed for TCBs not running
        in storage protect key 8.
    11. Support for VS COBOL II Rel 2.0 added.
    12. Only one valid_info entry should be collected (working-
        storage length). Extraneous adds of valid_info removed.
    13. The code has been changed to deal with the unnamed section.
    14. The logic has been changed.
    15. Fault Analyzer will no longer attempt to analyze abends
        which occur in the job scheduler IEESB605 TCB but will
        instead issue message IDI0123S.
    16. Parameter storage accessibility now checked.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM70211

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655W4600

  • Reported release

    B10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST

  • Submitted date

    2012-08-03

  • Closed date

    2012-10-10

  • Last modified date

    2012-11-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK82503

Modules/Macros

  • HADQB10J IDIALLOC IDICAASM IDICABND IDICALE
    IDICALOC IDICASUB IDICCFND IDICISA  IDICNF00 IDICNOTR IDICOP
    
    ***This field was truncated.  To obtain the full apar record, please contact your local support center.***
    

Publications Referenced
SC19313105        

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655W4600

Applicable component levels

  • RB10 PSY UK82503

       UP12/10/16 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Document information

More support for: Fault Analyzer for z/OS

Software version: B10

Reference #: PM70211

Modified date: 2012-11-07