Fixes are available
7.1.0.3-TIV-ITCAMAD-IF0004: ITCAM for Application Diagnostics V7.1 FP3 IF4
7.1.0.3-TIV-ITCAMAD-IF0005: ITCAM for Application Diagnostics V7.1 FP3 IF5
7.1.0.3-TIV-ITCAMAD-IF0004: ITCAM for Application Diagnostics V7.1 FP3 IF6
7.1.0.3-TIV-ITCAMAD-IF0008: ITCAM for Application Diagnostics V7.1 FP3 IF8
IBM Tivoli Composite Application Manager for Application Diagnostics V7.1 fixes
APAR status
Closed as program error.
Error description
PMI settings do not work in datacollector_global_custom.properties When PMI settings (am.was6custompmi.settings.1=..., etc) are specified in datacollector_global_custom.properties, they do not take effect.When exactly the same datacollector_global_custom.properties file is copied to datacollector_custom.properties in the app server "custom" directory, the PMI settings requested work as expected. BTW, the same problem exists for distributed datacollectors! I ran through all the unit tests for this feature on the toolkit and everything worked just fine. However, when it is run with the shared data collector, there is one situation that fails. Any property in datacollector_global_custom.properties will be applied to all DCs except if a property of the same name already exists in the server datacollector.properties. The datacollector.properties file that is distributed with the product contains two PMI properties am.was6custompmi.settings.1=threadPoolModule=3,4 am.was6custompmi.settings.3=servletSessionsModule=7,17,6,14,9,1, 11,10,13,12,2,4,8,15,16 Any other PMI modules can be overridden in global except these two. The native toolkit loads all properties files in a predefined order (global, base, local) and does not overwrite a property that already exists. The DC reads the properties files but does not honor that order properly.
Local fix
The only workaround is to supply these two properties in the local rather than the global template.
Problem summary
Global datacollector properties do not override datacollector,properties if property already exsists.
Problem conclusion
Order of property files merge is corrected.
Temporary fix
Comments
APAR Information
APAR number
PM69424
Reported component name
ITCAM WAS ZOS D
Reported component ID
5698A7100
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-07-23
Closed date
2012-09-08
Last modified date
2017-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITCAM WAS ZOS D
Fixed component ID
5698A7100
Applicable component levels
R710 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3PGL","label":"Tivoli Composite Application Manager for WebSphere"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
07 January 2022