PM69304: RDZ 85 ENVIRONMENT VARIABLE _CMDSERV_BASE_HOME NOT SET

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Environment variable _CMDSERV_BASE_HOME not set in rsed.envvars
    

Local fix

  • add the following to the end of rsed.envvars
    _CMDSERV_BASE_HOME=$CGI_ISPHOME
    _CMDSERV_CONF_HOME=$CGI_ISPCONF
    _CMDSERV_WORK_HOME=$CGI_ISPWORK
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: 01.all RDz users                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01.rsed.envvars is missing              *
    *                         _CMDSERV_*_HOME=$CGI_ISP* statements *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    01.after the rename of _CMDSERV_*_HOME to CGI_ISP*, the
       _CMDSERV_*_HOME=$CGI_ISP* compatibility statements were not
       added to rsed.envvars
    

Problem conclusion

  • 01.rsed.envvars now has the _CMDSERV_*_HOME=$CGI_ISP*
       compatibility statements
       _CMDSERV_BASE_HOME=$CGI_ISPHOME
       _CMDSERV_CONF_HOME=$CGI_ISPCONF
       _CMDSERV_WORK_HOME=$CGI_ISPWORK
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM69304

  • Reported component name

    RD/Z HOST

  • Reported component ID

    5724T0723

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-07-20

  • Closed date

    2012-11-20

  • Last modified date

    2012-12-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FEKFENVR
    

Fix information

  • Fixed component name

    RD/Z HOST

  • Fixed component ID

    5724T0723

Applicable component levels

  • R850 PSY UK83670

       UP12/12/14 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.