A fix is available
APAR status
Closed as program error.
Error description
ERROR DESCRIPTION: You can't do a collection after new maintenance. After you put on maintenance, 1204, which contains migration changes, you get the following error message: CICS LOAD YIUXITTB failed RESP=27 RESP2=3 RCODE=01000000 CINT has abended IUZA in program CIUA110C CINT session has ended Somehow it's trying to go to YIUXITTB instead of CIUXITTB. The CIUCNTL file was migrated from CICS IA 3.1 to 3.2 with error. Additional Symptom(s) Search Keyword(s): KIXREVCTC CIU2258I TRUE_INCLUDE_LIST='Y.......' The 'Y' value is the reason for the subsequent messages: CIU2201S CICS LOAD Y....... failed RESP=27 RESP2=1 RCODE=01000000 CIU2218S CINT has abended IUZA in program CIUA110C The CIU260 General Options for the region shows: 'TRUEs Include list' without the default value of CIUXITTB
Local fix
LOCAL FIX: I suggest the temporary solution to start collector. Start CINT transaction, select 2 - Configure Region Options, select 4 - Options against DEFAULTS, select 1 - General Options set 'TRUEs Include list' value as CIUXITTB, set 'Dynamic call' value as you need. press 'Enter'. Now you can start collector.
Problem summary
**************************************************************** * USERS AFFECTED: All CICS IA V3.2 users who will migrate * * CICS IA V3.1 to CICS IA V3.2. * **************************************************************** * PROBLEM DESCRIPTION: During migration from CICS IA v3.1 to * * CICS IA v3.2 file hlq.CIUCNTL is * * incorrectly transformed to v3.2 format. * **************************************************************** * RECOMMENDATION: Apply the PTF and perform the HOLD actions. * **************************************************************** The format of the file hlq.CIUCNTL is different between CICS IA v3.1 and v3.2. So transfer that file from CICS IA v3.1 to v3.2, using IDCAMS (REPRO) utility is incorrect. The new program to transform file hlq.CIUCNTL from CICS IA v3.1 to v3.2. should be created.
Problem conclusion
Program CIUMIGVG has been created to transform file hlq.CIUCNTL from CICS IA v3.1 to v3.2.
Temporary fix
Comments
APAR Information
APAR number
PM68128
Reported component name
CICS INTER ANAL
Reported component ID
5655U8600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2012-07-03
Closed date
2012-09-20
Last modified date
2012-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK81970
Modules/Macros
CIUCFUPD CIUMIGVD CIUMIGVF CIUMIGVG CIUUREG H274320J
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5655U8600
Applicable component levels
R320 PSY UK81970
UP12/10/04 P F210
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
10 December 2012