A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 11 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. Fault Analyzer reporting U4038 as * * the point of failure when a later * * abend (S0C7 or other) was the real * * cause. * * APAR PM65723 * * 02. Storage not accessible when * * reporting COBOL storage using * * SYSDEBUG side file and OPT(FULL) * * compiler option. * * APAR PM66372 * * 03. IDILANGX issues message IDISF8158T * * when processing Enterprise COBOL * * compiler listing. * * APAR PM65777 * * 04. The user is viewing CICS TS 4.2 * * SM domain panels and is seeing * * subpools displayed in the wrong * * DSA. * * APAR PM68869 * * 05. The user is viewing CICS SDUMP * * panels, looking at TCP MRO * * information and is seeing * * incorrect information, like the * * 'CONN' values in the MRO * * Conversation Summary. * APAR PM68870 * * 06. Abend S0C4 in IDIXDCAP+2FF6 * * DUBBEDER+2F8 with reg 9 at a bad * * address. * * APAR PM68997 * * 07. Message IDAI1001E.PUT FAILED, ERROR * * FOUND WHILE UPDATING THE INDEX * * issued by the IDIS subsystem * * shortly after start-up. * * APAR PM68808 * * 08. The user is looking at a CICS 4.2 * * transaction abend analysis and * * finds that the CICS trace does not * * contain the entries which lead * * up to the abend. * * APAR PM69465 * * 09. A user who is analyzing a CICS * * SDUMP sees FA abend 0C4 in * * PP_LG_STREAM_SUMM. * * APAR PM69466 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. An earlier exception, such as IGZ0014W from IGZEOPT that is recovered, might be incorrectly reported as the point of failure. 02. OPT(FULL) removes unreferenced data items but they are still found in the SYSDEBUG attribute table, and when processed attempt to consume unavailable storage. 03. Source line grid margin character '!' instead of expected '|'. 04. CICS TS 4.2 changed an array, but the FA panel script was not updated, so it is getting subpool information from the wrong place. 05. The Fault Analyzer panel is sorting the information that it is displaying incorrectly, leading to data being displayed in the wrong place. 06. Intermittent abend S0C4 in IDIXDCAP after Fault Analyzer has been called to capture an abend. 07. An automatic update of the Fault Analyzer IDIVSENU VSAM message and abend code explanation repository, during start-up of the IDIS subsystem, caused the KSDS index to become corrupted due to using POINT with only a partial key prior to using PUT when inserting records. 08. The Fault Analyzer code which captures CICS 4.2 trace entries is calculating the start/size/end of the trace capture incorrectly. 09. FA is analyzing a CICS SDUMP which has severely corrupted LG Domain control blocks. The analysis code abends because it doesn't handle the corrupted control block chains.
Problem conclusion
01. Tests for earlier abends updated. 02. Unreferenced data items in the SYSDEBUG attribute table are now ignored. 03. IDILANGX accepts '!' as grid right margin character. 04. FA script panels for the SM domain have been updated to use the new format array whan processing 4.2 SDUMPS. 05. The panel sort mechanism has been fixed. 06. The ESTAEX regester restore for R9 has been corrected. 07. The full key is now being used with POINT prior to PUT. 08. Fault Analyzer has been changed to calculate the start/size/end of the captured trace entries correctly, as happened with previous CICS versions. 09. IDIECLG PP_LG_STREAM_SUMM has been changed to terminate analysis of the LG control block chain if it is corrupted.
Temporary fix
Comments
APAR Information
APAR number
PM67620
Reported component name
FAULT ANALYZER
Reported component ID
5655W4600
Reported release
B10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-06-25
Closed date
2012-07-26
Last modified date
2012-09-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK80578
Modules/Macros
HADQB10J IDIALLOC IDICAASM IDICABND IDICALE IDICALOC IDICASUB IDICCFND IDICISA IDICNF00 IDICNOTR IDICOP ***This field was truncated. To obtain the full apar record, please contact your local support center.***
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655W4600
Applicable component levels
RB10 PSY UK80578
UP12/08/07 P F208
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: