IBM Support

PM66180: EYUXU0203E METHOD FAILURE IN XDBX RESPONSE 02 REASON 04. ASRA S0C4 IN METHOD MOFS, TRAN XDBM

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • You are using CPSM BATCHREP either through the WUI or by a batch
    job. The output of your BATCHREP contains a message similar to
    the following:
    .
    EYUXU0203E Method failure in (XDBX) - response (02) - reason
    (04).
    .
    In the CMAS job log, you see an ASRA / S0C4 has occurred, with
    messages similar to the following:
    .
    .
    DFHDU0205 CMASJOB A SYSTEM DUMP FOR DUMPCODE: AP0001  , WAS
              SUPPRESSED BY THE DUMP TABLE OPTION FOR THIS DUMPCODE
    EYUXL0900I   Starting Environment Recovery
    EYUXL0905E CMASJOB ASRA IN MOFS, OFFSET 00000D7E
               PSW=078D5000 960BDB4E
    EYUXL0905E INTC=0011 ILC=4 TXCP=00936001 SCODE=S00C4
               TRAN=XDBM TASK=#####
    EYUXL0905E Methods=MOFS,XDBX,XDBM,XLOP
    EYUXL0905E BEAR=160BD5A0, OFFSET=000007D0
    EYUXL0906I Registers at ABEND
    EYUXL0907I GPR0-GPR1  00000B43_16505020  00000003_16504978
    EYUXL0907I GPR2-GPR3  00000000_00800EB0  00000000_160C07C8
    EYUXL0907I GPR4-GPR5  00000000_160C17C8  00000000_001352CB
    EYUXL0907I GPR6-GPR7  00000000_160BD5A0  00000000_00000000
    EYUXL0907I GPR8-GPR9  00000000_00000001  00000000_16504EA8
    EYUXL0907I GPRA-GPRB  00000000_FFFFFFFF  00000000_00000001
    EYUXL0907I GPRC-GPRD  00000000_167CCDAC  00000000_16504170
    EYUXL0907I GPRE-GPRF  01FF0040_0093617B  00000002_16504AA2
    EYUXL0907I ARR0-ARR3  00000000  00000000  00000000  00000000
    EYUXL0907I ARR4-ARR7  00000000  00000000  00000000  00000000
    EYUXL0907I ARR8-ARRB  01FF0054  00000000  01FF0054  00000000
    EYUXL0907I ARRC-ARRF  00000000  00000000  00000000  00000000
    EYUXL0907I FPR0-FPR1  00000000_00000000  00000000_00000000
    EYUXL0907I FPR2-FPR3  00000000_00000000  00000000_00000000
    EYUXL0907I FPR4-FPR5  00000000_00000000  00000000_00000000
    EYUXL0907I FPR6-FPR7  00000000_00000000  00000000_00000000
    EYUXL0907I FPR8-FPR9  00000000_00000000  00000000_00000000
    EYUXL0907I FPRA-FPRB  00000000_00000000  00000000_00000000
    EYUXL0907I FPRC-FPRD  00000000_00000000  00000000_00000000
    EYUXL0907I FPRE-FPRF  00000000_00000000  00000000_00000000
    EYUXL0907I FPCR       00000000
    EYUXL0908I Storage At ABEND
    EYUXL0909I -20  005D585C  003C9240  D939D2FD  D93AD939
    EYUXL0909I -10  5870D8E8  18A75EA0  3CD851E0  50001EE2
    EYUXL0909I +00  44A0305A  D219DB86  D9381867  18875E80
    EYUXL0909I +10  3CD84480  3030A77E  0001A774  00159240
    EYUXL0910I  EYU9XLRV
    Dump,CMASJOB,CMASJOB,MV30,CMAS,XDBM,#####,ASRA,EYU0MOFS,
         MM/DD/YYYY,HH:MM:SS
    EYUXL0999I XLRV Exiting Successfully
    .
    IEA794I SVC DUMP HAS CAPTURED:
    DUMPID=xxx REQUESTED BY JOB (CMASJOB)
    DUMP TITLE=EYU9XLRV Dump,CMASJOB,CMASAPPL,MVSX,CMAS,
         XDBM,#####,ASRA,EYU0MOFS,MM/DD/YYYY,HH:MM:SS
    .
    In the registers that are traced in the job output, general
    purpose register 10 (GPRA) contains negative 1, (-1),
    00000000_FFFFFFFF.
    .
    Additional Keywords/Symptoms:
    EYU9XLRV Dump XDBM ASRA EYU0MOFS
    KIXREVNDB
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V4R1M0 and V4R2M0 Users      *
    ****************************************************************
    * PROBLEM DESCRIPTION:    You are using CPSM BATCHREP either   *
    *                      through the WUI or by a batch job, to   *
    *                      CREATE a CSYSDEF object.  The output of *
    *                      your BATCHREP contains the following    *
    *                      message:                                *
    *                      .                                       *
    *                           EYUXU0203E Method failure in       *
    *                              (XDBX) - response (02) -        *
    *                              reason (04).                    *
    *                      .                                       *
    *                      In the CMAS job log, you see abend ASRA *
    *                      (S0C4) has occurred, at offset +000D7E  *
    *                      in module EYU0MOFS (MOFS - MOS Field    *
    *                      Services).                              *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes which act as Maintenance    *
    *                 point for one or more CICSplexes must be     *
    *                 recycled to pick up the new code.  Note      *
    *                 that CMASes do not need to be brought down   *
    *                 and restarted at the same time.              *
    ****************************************************************
       Module EYU0MOFS is called during resource creation to con-
    vert attribute values from external to internal form.  When
    testing character attributes for the special INHERIT values
    '*' or 'INHERIT' local variables used to determine the address
    and length of the value to be compared are not initialized.
    Abend S0C4 might occur if these variables contain residual
    data.
    

Problem conclusion

  •    Module EYU0MOFS was modified to use the starting address
    and length passed in the Method Argument List when testing
    character attributes for special values.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM66180

  • Reported component name

    CICS TS Z/OS V4

  • Reported component ID

    5655S9700

  • Reported release

    70M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-06-05

  • Closed date

    2012-06-14

  • Last modified date

    2012-07-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK79605 UK79606

Modules/Macros

  •    DYU0MOFS EYU0MOFS
    

Fix information

  • Fixed component name

    CICS TS Z/OS V4

  • Fixed component ID

    5655S9700

Applicable component levels

  • R60M PSY UK79605

       UP12/06/18 P F206

  • R70M PSY UK79606

       UP12/06/18 P F206

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Document information

More support for: CICS Transaction Server

Software version: 4.2

Reference #: PM66180

Modified date: 02 July 2012


Translate this page: