A fix is available
APAR status
Closed as program error.
Error description
Customer ran the GENJCL.CA GRPNAME() command and generated a CA JCL with a list of DB and purge time under the //SYSIN DD. Before the CA job execution, an IMS archive job completed and added one more SLDS to the end of PRISLD record. The new SLDS caused the selected purge time (in the CA DB0 card) invalid. When the CA job continued to execute, it issued DSP0715E to report the invalid purge time. We expect the message DSP0714I in this situation, not the message DSP0715E. .
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS V12 users running the IMS Change * * Accumulation utility with full function * * data bases in the Change Accumuation * * group. * **************************************************************** * PROBLEM DESCRIPTION: DSP0715E is issued for a full * * function database. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** Message DSP0715E is issued when a full function database is in a Change Accumulation group and the purge time for the concurrent image copied has changed since the CA JCL was created. MSGDSP0715E
Problem conclusion
GEN: KEYWORDS: *** END IMS KEYWORDS *** The determine purge time module has been changed to add a check to continue looking for an earlier log when the DB0 timestamp in the SYSIN statement does not match the checkpoint id on the log selected for full function databases.
Temporary fix
Comments
APAR Information
APAR number
PM65842
Reported component name
IMS V12
Reported component ID
5635A0300
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-05-30
Closed date
2012-11-30
Last modified date
2013-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK83927
Modules/Macros
DSPICP00
Fix information
Fixed component name
IMS V12
Fixed component ID
5635A0300
Applicable component levels
R200 PSY UK83927
UP12/12/06 P F212
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date: