Error description
CDC for z/OS detects when a column is added to a table being mirrored, makes internal adjustments for the new column, and automatically continues mirroring the table, not including the newly added column. Some customers need the subscription to end when the new column is added, so that the newly added column can be added to the list of columns being replicated.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CDC for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: CDC for z/OS always continues to mirror * * a table when a new column is added to * * the table. This does not give the user * * a change to change the table mapping * * when the column is added. * **************************************************************** * RECOMMENDATION: * **************************************************************** The DDL resiliency feature of CDC for z/OS caused it to make the necessary internal adjustments in order to continue mirroring a table after a column is added to the table. There was no provision made for the user to cause the subscription to end so that table mappings could be adjusted.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PM65640
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
650
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-05-28
Closed date
2012-05-28
Last modified date
2016-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK79132
Modules/Macros
CHCDLSGP CHCDSCPF CHCTVHDL CHCTVHDL
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
R650 PSY UK79132
UP12/06/02 P F206
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.5","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.5","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 March 2016