A fix is available
APAR status
Closed as program error.
Error description
Locate within a PDS in RSE view positions to the wrong member. One member name contains @ or ￵ 1) Right-click any PDS 'show in table' 2) Table opens in 'remote system details' 3) Now CRTL + L and choose an unknown member name PUE - 4) Wrong result from RSE. The top of the member list is wrongly highlighted and not the correct position. Expected was that the highlighted member would be PU￵ SUPAE -
Local fix
Either don't use the "show in table" feature or upgrade to RD/z 8.0.3.2.
Problem summary
When the Remote System Details view was opened, the locate action was handled by it first and then Remote Systems View was updated with incorrect location.
Problem conclusion
The RDz client was fixed to handle the locate action in the Remote Systems view correctly. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V7.6.2.4 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PM65578
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-25
Closed date
2012-08-23
Last modified date
2012-08-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R762 PSY
UP