A fix is available
APAR status
Closed as program error.
Error description
When running the FM batch DSI function, and volser is specified, data set information for the cataloged data set is displayed instead of the data set on the specified volser.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All File Manager Users * **************************************************************** * PROBLEM DESCRIPTION: 1. When using the DSI function * * specifying a VOLSER parameter to * * display information for an * * uncatalogued data set, information for * * a catalogued data set with the same * * name is reported. * * 2. The Volume serial field is ignored * * when displaying the extents of an * * uncatalogued data set (option 5.6). * * 3. When viewing a load module using * * the V prefix command on the Load * * Module Compare Member List panel the * * wrong module may be displayed if * * either of the libraries is * * uncatalogued. * * 4. When printing a member from a * * Member Selection List panel using the * * Print prefix command and a volume was * * supplied on the initial function entry * * panel this volume is not being passed * * to the Print Utility panel. * * 5. When printing multiple members from * * a Member Selection List panel using the * * Print prefix command and the library is * * an uncatalogued data set the message * * 'IEC130I SYS00nnn DD STATEMENT MISSING' * * may be displayed. * * 6. When editing and executing a DB2 SQL * * statement from a data set (option 4.4) * * and a Volume is specified for the * * input data set and there are * * catalogued and uncatalogued data sets * * with the same name the catalogued data * * set will always be used and the Volume * * parameter ignored. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 1,2,6. These functions are not using the VOLSER parameter provided when obtaining the information for a data set. 3. The wrong VOLSER parameter may be used when viewing a load module which has been invoked using the V prefix command. 4. The volume specified on the function entry panel is not being passed to the Print Utility. 5. The allocated input data set is being incorrectly freed.
Problem conclusion
1. The DSI function will report details of the correct data set when the VOLSER paramater is provided. 2. The correct extent information will be displayed for an uncatalogued data set (option 5.6). 3. The correct load module will be displayed when viewed from a load module member selection list. 4. If a volume number was supplied on the initial entry panel this volume number will be entered in the Print Utility panel Volume field. 5 & 6. This problem has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PM63834
Reported component name
FILE MANAGER Z/
Reported component ID
5655W4700
Reported release
B10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-05-03
Closed date
2012-07-25
Last modified date
2012-08-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FMN0LVL FMN2LVL
Fix information
Fixed component name
FILE MANAGER Z/
Fixed component ID
5655W4700
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAV","label":"File Manager for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
08 August 2012