A fix is available
APAR status
Closed as program error.
Error description
The CSLULGTP function (return output in STEM variable) went into a 100% CPU loop if the OM task is missing (stopped). The loop is in module CSLULFM1 SCANIT procedure, scanning the Response Buffer for XML Tags
Local fix
Start OM
Problem summary
**************************************************************** * USERS AFFECTED: All IMS V11 users using REXX SPOC API * **************************************************************** * PROBLEM DESCRIPTION: IMS REXX SPOC API function CSLULGTP * * goes into a 100% CPU loop if the OM * * task is missing. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** The IMS REXX SPOC API function CSLULGTP() - Retrieve command responses directly to REXX stem variables - goes into a loop if the OM task is missing because of a logic error in module CSLULFM1. CSLULFM1 calls an internal procedure within a loop. When OM is missing the procedure returns with RC=8. In this situation CSLULFM1 does not set the required controls to exit the loop and begins looping forever.
Problem conclusion
GEN: KEYWORDS: *** END IMS KEYWORDS *** The following part was updated: CSLULFM1 The CSLULFM1 routine was modified to set the proper controls when a non-zero RC is received from internal procedure calls to prevent the endless loop.
Temporary fix
The fix for this APAR is BAD. If you need to apply the fix for this APAR to resolve a problem, you must also apply the fix for APAR PM63746. AE12/19/12
Comments
APAR Information
APAR number
PM63746
Reported component name
IMS V11
Reported component ID
5635A0200
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-02
Closed date
2012-12-07
Last modified date
2013-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CSLULFM1
Fix information
Fixed component name
IMS V11
Fixed component ID
5635A0200
Applicable component levels
R100 PSY UK90140
UP13/02/14 P F302
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.