Fixes are available
Rational Software Architect, Version 8.0.4.1
Rational Software Architect for WebSphere Software, Version 8.0.4.1
Rational Software Architect for WebShpere Software 7.5.5.5 Interim Fix 001
Rational Software Architect Standard Edition 7.5.5.5 Interim Fix 001
Rational Software Modeler 7.5.5.5 Interim Fix 001
APAR status
Closed as program error.
Error description
Environment: - Microsoft Windows XP SP3 / Windows 7 - IBM Rational Software Architect 7.5.5.5 or 8.0.4 Reproducible Y/N: Y Description of problem: If you have a URL displayed in a diagram that points to a html/htm file, the time to load the diagram increases dramatically. Steps to reproduce 1. Create a UML Project using all the default 2. In the created model, open a diagram 3. Add a URL (right click add UML-? URL 4. Type or copy the URL : http://publib.boulder.ibm.com/infocenter/rsahelp/v8/index.jsp?to pic=/com.ibm.xtools.gs_using_rsx.doc/topics/c_gs_essentials_of_r sa_mod19.html 5. In the display name field type 'Test'. 6. Close the diagram 7. Save the model 8. Open the diagram again it will take a much longer time to open... up to more than one minute Workaround None
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** Diagram displaying URL pointing to htm/html can take more than a minute to open
Problem conclusion
The edit part for comments loads all the information in a URL, and tries to identify if it represents any known image format. Instead of this, it would now check the content type of the URL to do the same.
Temporary fix
Comments
APAR Information
APAR number
PM61266
Reported component name
SW ARCHITECT WI
Reported component ID
5724I7001
Reported release
755
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-03-27
Closed date
2012-12-06
Last modified date
2012-12-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SW ARCHITECT WI
Fixed component ID
5724I7001
Applicable component levels
R755 PSN
UP
Rate this page:
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.