PM60098: IWM4ECRE RC=00000008 RSN=03300828 ERROR WHEN USING ZIIP FUNCTION ON Z/OS 1.11.

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Problem was a PLISTVER parameter. A value of MAX was used,
    which generated parameters valid only for the compile level
    and above.  Removing the parameter caused an appropriate
    default to be used that is valid at all levels.
    

Local fix

  • MM/MM
    STRRTC 315207
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Sterling Connect:Direct V5.1.X  *
    ****************************************************************
    * PROBLEM DESCRIPTION: IWM4ECRE RC=00000008 RSN=03300828       *
    *                      ERROR WHEN USING ZIIP FUNCTION ON       *
    *                      Z/OS 1.11.                              *
    ****************************************************************
    * RECOMMENDATION: Apply this maintenance....                   *
    ****************************************************************
    IWM4ECRE RC=00000008 RSN=03300828 ERROR WHEN USING ZIIP
    FUNCTION ON Z/OS 1.11.
    

Problem conclusion

  • IWM4ECRE RC=00000008 RSN=03300828 ERROR WHEN USING ZIIP
    FUNCTION ON Z/OS 1.11.
    KEYWORDS: ZOS0201T/K
    

Temporary fix

  • ZOS111T/K
    *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PM60098

  • Reported component name

    STR CD FOR Z/OS

  • Reported component ID

    5655X0100

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-03-09

  • Closed date

    2012-03-13

  • Last modified date

    2013-05-07

  • APAR is sysrouted FROM one or more of the following:

    PM58862

  • APAR is sysrouted TO one or more of the following:

    UK77026

Modules/Macros

  •    DGADZIIP
    

Fix information

  • Fixed component name

    STR CD FOR Z/OS

  • Fixed component ID

    5655X0100

Applicable component levels

  • R510 PSY UK77026

       UP12/03/16 P F203

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Sterling Connect:Direct

Software version:

5.1

Reference #:

PM60098

Modified date:

2013-05-07

Translate my page

Machine Translation

Content navigation