PM58331: Incorrect behavior in match event (TLOG#69857)

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • Customer has observed an incorrect behavior in match event when
    the reception template has several alternatives for the same
    type. If the  type value is  omit  and the template has two
    alternatives, the first  one is a specific value and the other
    one is the value  omit , then the match event finishes with
    mismatch.
    
    You can find this behavior in the attached project when you
    compile and execute the TC_Matching(). In the Execution tab you
    will see the next log:
    
    
    NAS_TrackingArea_UG_UTRAN.ttcn (1342): [UTRAN_PTC:1]
    template_mismatch: 'does not match template parameter 'p_Pdu''
    for 'car_RLC_Data_Ind.data.
    aM_message.uL_DCCH_Message': Expected {?anyornone?,
    
    {radioBearerSetupComplete := {0, ?anyornone?, ?anyornone?,
    ?anyone?,
    ?anyornone?, ?anyornone?, ?anyornone?, ({?anyornone?,
    ({{?anyornone?,
    omit}, ?anyornone?}, omit)}, omit)}}}, got
    
    {{'10110010011010010110100111100010'B, 2},
    {radioBearerSetupComplete :=
    {0, omit, omit, '00000000000000000010'B, omit, omit, omit,
    omit}}}
    
    
    The match event must finish with  true  because the value of
    v_data is:
    {{'10110010011010010110100111100010'B, 2},
    {radioBearerSetupComplete := {0, omit, omit,
    '00000000000000000010'B, omit, omit, omit, omit}}} and  the last
     omit  has to match with ({{?anyornone?, omit}, ?anyornone?},
    
    omit)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Customer has observed an incorrect behavior in match event
    when the reception template has several alternatives for the
    same type.
    

Problem conclusion

  • fixed in 3.3.0.6
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM58331

  • Reported component name

    TLOGIC TESTER

  • Reported component ID

    5724V70TE

  • Reported release

    330

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-02-16

  • Closed date

    2012-12-12

  • Last modified date

    2012-12-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC TESTER

  • Fixed component ID

    5724V70TE

Applicable component levels

  • R330 PSN

       UP