APAR status
Closed as program error.
Error description
Programs and files are created as expected in th JCL flow. However EDIN TSQ's are residue in CICS storage. Doesn't seem to matter if there is content to extract or not
Local fix
STRRTC = 312623 MAH / MAH Only manually purging the TSQ is the resolve.
Problem summary
Users Affected: Gentran z/OS 6.4, 6.5, & 6.6 customers running EDID205 Extract program while used in CONCURRENCY setup. Problem Description: EDID205 Extract program while used in the CONCURRENCY setup is processing and finishing the extraction from the databank, but the created EDIN#### TSQ is not purged when finish. Leaving it in storage.
Problem conclusion
Resolution Summary: Fixed EDID205 EOJ to delete the TSQ by calling EDIBDBOE with the DT entry point. Delivered In: 6.6.0.1, 6.4 Cumfix, 6.5 Cumfix
Temporary fix
Comments
APAR Information
APAR number
PM57929
Reported component name
GENTRAN BASIC F
Reported component ID
5655X0701
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-10
Closed date
2012-05-18
Last modified date
2012-05-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
GENTRAN BASIC F
Fixed component ID
5655X0701
Applicable component levels
R640 PSY
UP
R650 PSY
UP
R660 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.