IBM Support

PM55677: STUBS AND TIES GENERATED FOR EJB 3.0 ARE NOT COMPATIBLE WITH STUBS AND TIES GENERATED BY RMIC

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • RMI/IIOP interfaces generated for EJB 3.0 are not backward
    compatible, which might cause errors such as
    
    java.lang.OutOfMemoryError
    at com.ibm.rmi.iiop.CDRReader.readBytesForString
    (CDRReader.java:2279)
    at com.ibm.rmi.iiop.CDRReader.readStringOrIndirection
    (CDRReader.java:472)
    at com.ibm.rmi.iiop.CDRReader.read_codebase_URL
    (CDRReader.java:2852)
    at com.ibm.rmi.iiop.CDRReader.fast_read_value
    (CDRReader.java:1893)
    at com.ibm.rmi.iiop.CDRReader.read_value
    (CDRReader.java:2000)
    at com.ibm.example._EJB3_Stub.method(Unknown Source)
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • PM55677 is a sysroute of APAR PM46698. APAR PM55677 was taken to
    deliver a ++APAR. APAR PM55677 is being closed DUP of APAR
    PM54062 because PM54062 will document the delivery of APAR
    PM46698 in Service Level (Fix Pack) 7.0.0.21 of WebSphere
    Application Server V7.0 for z/OS.
    

APAR Information

  • APAR number

    PM55677

  • Reported component name

    WEBSPHERE FOR Z

  • Reported component ID

    5655I3500

  • Reported release

    700

  • Status

    CLOSED DUA

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-01-10

  • Closed date

    2012-10-19

  • Last modified date

    2012-10-19

  • APAR is sysrouted FROM one or more of the following:

    PM46698

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]