A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 10 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. The user has specified EXCLUDE for * * a dumpcode. FA is excluding FA * * processing, but CICS goes on to * * take a transaction dump. * * The customer does not want this. * * APAR PM59057 * * 02. Fault Analyzer ISPF interface does * * not check product ENABLE/DISABLE * * status in IFAPRDxx. * * APAR PM59063 * * 03. Message IDI0144E Fault Analyzer * * IDIS subsystem error when //CEEOPT * * DD with HEAPPOOLS(ON) is used. * * APAR PM57765 * * 04. IDIMAPS data set not found during * * CICS start up. * * APAR PM59059 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. Fault Analyzer is not passing the result of EXCLUDE processing to CICS. 02. The check to see if Fault Analyzer had been disabled in IFAPRDxx had only been made for real-time analysis. 03. The cross memory call to the IDIS subsystem will fail with message IDI0144E if HEAPPOOLS(ON) is set. 04. Configuration module IDICNFUM was not being used correctly during Fault Analyzer's CICS startup processing.
Problem conclusion
01. Fault Analyzer has been changed so that EXCLUDE processing will pass UERCBYP (bypass this transaction dump) if the abend code is excluded. 02. The ISPF interface now checks IFAPRDxx. 03. The HEAPPOOLS(OFF) option is now set in the start of IDIDA. 04. IDICNFUM is now being used correctly.
Temporary fix
Comments
APAR Information
APAR number
PM54423
Reported component name
FAULT ANALYZER
Reported component ID
5655V5100
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-12-14
Closed date
2012-03-01
Last modified date
2012-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK76704
Modules/Macros
IDICABND IDICALE IDICALOC IDICASUB IDICCFND IDICISA IDICOPYR IDICSV12 IDIDA IDIGSVRI IDIGSVRP IDIGUIP IDILANGP IDILANGX IDIMCICS IDINDEX IDIPBRWS IDIPDDIR IDIPDSCU IDIPH106 IDISAMAN IDISAQUE IDISCJST IDISDB2P IDISDB2S IDISFPEX IDISIFND IDISJAVA IDISJLD IDISLKUP IDISLOG IDISMAIN IDISREG IDISRFRA IDISRFRD IDISTIME IDISUPDI IDISVIEW IDIUTIL IDIWDATA IDIXALOG IDIXASUB IDIXCCEE IDIXCC52 IDIXCEE IDIXCX52 IDIXCX53 IDIXDCAP IDIXDSAC IDIXDUMP IDIXGSPC IDIXGSPS IDIXOPT IDIXSNAP
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655V5100
Applicable component levels
RA10 PSY UK76704
UP12/03/20 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
03 April 2012