Fixes are available
IBM Rational Rose Enterprise 7.0.0.4 iFix003
IBM Rational Rose Modeler Edition 7.0.0.4 iFix003
IBM Rational Rose Professional Ada Edition 7.0.0.4 iFix003
IBM Rational Rose Professional C++ 7.0.0.4 iFix003
IBM Rational Rose Professional Data Modeler 7.0.0.4 iFix003
IBM Rational Rose Professional J Edition 7.0.0.4 iFix003
IBM Rational Rose Professional Edition for Visual Basic 7.0.0.4 iFix003
APAR status
Closed as program error.
Error description
myOp2 11:15:33| Exceptions: MyException 11:15:33| --- Done The last exception added is not fully qualified. You have to reload or restart again Rose to get the fully qualification. This was not required with Rose 2003 SR5 but since then the functionality is broken. Workaround: Reload or restart again Rose to get the fully qualification after each exception addition
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The Rose Extensibility Interface call to get the Exceptions from the Operations (eg aOper.Exceptions) will only return the fully qualified name/path if the exception(s) was/were added before Rose was started. Any new addition during the current Rose session will be returned by the REI call with the simple name. After the restart of Rose or the reloading of the model, all the exceptions added in the previous session will be output with their fully qualified name.
Problem conclusion
The exceptions REI call has been modified to return fully qualified exceptions
Temporary fix
Comments
APAR Information
APAR number
PM51786
Reported component name
ROSE ENTERPRISE
Reported component ID
5724G5002
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-11-08
Closed date
2012-07-20
Last modified date
2012-07-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ROSE ENTERPRISE
Fixed component ID
5724G5002
Applicable component levels
R700 PSN
UP
Rate this page:
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.