IBM Support

PM50956: UNSTALLING A PROCESS APPLICATION FAILS AND CAN'T BE STARTED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • When a process application fails to be uninstalled the
    application is left is a state where it can't be stopped,
    started or uninstalled. This is because the business-level
    application (BLA) and composition unit (CU) for the application
    are removed. These correspond to the BLAs and CUs folders
    under the config folder.
    -
    This is the scenario:
    1. You attempt to uninstall a process application.
    2. The BLA task runs before the WebSpere Process Server task.
    The BLA task removes the BLA and CU.
    3. The WebSpere Process Server task fails the uninstall
    expectly because the templates are active.
    CWWBF0025E: Process WFUUDemoFlowCarOrderingC40 of
    application WFUUDemoFlowCarOrderingC40App still has
    instances. Terminate and delete all process instances
    before updating or uninstalling a process application.
    4. You save the configuration.
    5. The application is still installed but without a BLA or CU
    for it.
    6. The application can not be stopped or started.
    7. The application can not be uninstalled.
    

Local fix

  • -
    Search Keywords: WPS BLA CU app install uninstall
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users of WebSphere Process Server.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Application cannot be accessed after    *
    *                      the application fails to uninstall.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    After the uninstallation of an application fails and the
    session is saved anyway, the application might not be able to
    be started, stopped, or uninstalled after uninstall corrective
    action is taken.
    

Problem conclusion

  • Business-level application and composition unit files in the
    configuration were deleted before uninstall validation had
    been completed. The problem has been corrected.
    
    APAR PM50956 is currently targeted for inclusion in
    Service Levels (Fix Packs)  of WebSphere
    Application Server 7.0.0.23 and 8.0.0.3
    

Temporary fix

Comments

  • PM50956 is a sysroute of APAR PM49821. APAR PM50956 was taken to
    deliver a ++APAR. APAR PM50956 is being closed DUP of APAR
    PM53810 because PM53810 will document the delivery of APAR
    PM49821 in Service Level (Fix Pack) 7.0.0.23 of WebSphere
    Application Server V7.0 for z/OS.
    

APAR Information

  • APAR number

    PM50956

  • Reported component name

    WEBSPHERE FOR Z

  • Reported component ID

    5655I3500

  • Reported release

    700

  • Status

    CLOSED DUB

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-10-26

  • Closed date

    2011-12-07

  • Last modified date

    2012-05-09

  • APAR is sysrouted FROM one or more of the following:

    PM49821

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: