PM40302: ABENDU3001 POSSIBLE AFTER SUBMITTING PROCESS WITH RETAIN=YES AND STARTT VALUE.

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • ABENDU3001 possible after submitting process with REATIN=YES and
    STARTT value.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Sterling Connect:Direct         *
    *                 V5.1.0                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: U3001 POSSIBLE AFTER SUBMITTING PROCESS *
    *                      WITH RETAIN=YES AND STARTT VALUE.       *
    ****************************************************************
    * RECOMMENDATION: Apply this maintenance.                      *
    ****************************************************************
    U3001 POSSIBLE AFTER SUBMITTING PROCESS WITH RETAIN=YES
    AND STARTT VALUE.
    

Problem conclusion

  • U3001 POSSIBLE AFTER SUBMITTING PROCESS
    WITH RETAIN=YES AND STARTT VALUE.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM40302

  • Reported component name

    SC DIRECT FOR Z

  • Reported component ID

    5655X0100

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-27

  • Closed date

    2011-06-02

  • Last modified date

    2012-12-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK68419

Modules/Macros

  • DGADICMN
    

Fix information

  • Fixed component name

    SC DIRECT FOR Z

  • Fixed component ID

    5655X0100

Applicable component levels

  • R510 PSY UK68419

       UP11/06/08 P F106

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Sterling Connect:Direct

Software version:

5.1

Reference #:

PM40302

Modified date:

2012-12-05

Translate my page