IBM Support

PM38332: WHEN RUNNING FM/IMS BATCH FUNCTION DIB (INITIALIZE), RECEIVE U0044 ABEND.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Receive U0044 abend when running FM/IMS DIB (Initialize)
    function and IMS subsystem is set up with DBRC=FORCE.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the FM/IMS Initialize function who  *
    *                 are attempting to initialize a full-function *
    *                 database.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: The job step that inserts a dummy       *
    *                      segment issues msgDFS044I 'DBRC         *
    *                      REQUIRED FOR THIS EXECUTION' and        *
    *                      terminates abnormally with IMS          *
    *                      abendu0044.                             *
    *                      The problem occurs when DBRC=FORCE is   *
    *                      specified in the IMS installation       *
    *                      defaults module DFSIDEF0.               *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The job steps that insert and delete a dummy segment execute
    with DBRC=N irrespective of the value specified for the DBRC
    parameter in the FM/IMS installations options module or the job
    steps.
    

Problem conclusion

  • The above mentioned job steps have been modified to use the DBRC
    value specified in either the job step (when it is specified
    there) or the FM/IMS installation options module (otherwise).
    When these job steps execute with DBRC=Y, the job step that
    deletes the dummy segment may issue msgDFS047A 'UNABLE TO OBTAIN
    AUTHORIZATION FOR DATA BASE xxxxxxxx. REASON CODE = 05.' and
    terminate abnormally with IMS abendu0047. This abend occurs
    if DBRC enforces the requirement of taking an image copy of the
    database after it has been loaded. If this requirement is
    enforced, an additional job step that resets the image copy
    status of the database data sets is required after the step that
    inserts a dummy segment and before the step that deletes the
    dummy segment.
    The FM/IMS Initialize dialog has been modified to generate this
    additional step when it may be required.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM38332

  • Reported component name

    FILE MANAGER ZO

  • Reported component ID

    5655V5200

  • Reported release

    A14

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-05-03

  • Closed date

    2011-08-18

  • Last modified date

    2011-09-01

  • APAR is sysrouted FROM one or more of the following:

    PM31483

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FMN1LVL
    

Fix information

  • Fixed component name

    FILE MANAGER ZO

  • Fixed component ID

    5655V5200

Applicable component levels

  • RA14 PSY UK70934

       UP11/08/24 P F108

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A14","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAV","label":"File Manager for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A14","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 September 2011