IBM Support

PM31979: CONTENT ARE NOT SYNCHRONIZED BETWEEN CLUSTER NODES

 

APAR status

  • Closed as program error.

Error description

  • WCM content is not updated on one of the cluster member. This
    makes the data inconsistent.
    
    The fix resolves this issue.
    

Local fix

Problem summary

  • This APAR is concerned with Navigator components only. The
    scenario is as follows
    
    1. Set up a clsuter with two nodes. The cluster must also be the
    subscriber in a syndicator-subscriber pair. For convenience of
    testing, you can syndicate to one of the nodes (say , NodeA) in
    the cluster.
    2. Create a navigator which displays some items and syndicate it
    to the cluster. Make sure you can view it correctly by hitting
    both nodes of the cluster directly.
    3. Now clear the navigator cache on NodeA only by running the
    clearcache.jsp or by restarting the node. Make sure you do not
    render the navigator now on either nodes.
    4. Now make an update to the navigator results on the syndicator
    and let the syndication go through. So we basically want NodeA
    to process this syndication update when its navigator cache is
    empty.
    5. Wait for few minutes (to ensure the cache has been
    replicated) and render the navigator on NodeB.
    

Problem conclusion

  • The cache removal messages are now sent even if the cache on
    NodeA ia empty.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM31979

  • Reported component name

    LOTUS WEB CONT

  • Reported component ID

    5724I2900

  • Reported release

    61C

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-07

  • Closed date

    2011-03-21

  • Last modified date

    2011-03-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    LOTUS WEB CONT

  • Fixed component ID

    5724I2900

Applicable component levels

  • R61C PSY

       UP

  • R700 PSY

       UP