IBM Support

PM27330: MISCELLANEOUS BUG FIXES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 10 users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. CICS transaction waits indefinitely *
    *                          for Fault Analyzer processing.      *
    *                          APAR PM33412                        *
    *                      02. Message IDI0063W deletion of fault  *
    *                          entry failed when using the V line  *
    *                          command to generate a saved report  *
    *                          and XFACILIT access is UPDATE.      *
    *                          APAR PM33413                        *
    *                      03. IDI0011S abend U4093 (X'FFD')       *
    *                          reason code X'90' when calling      *
    *                          IDISNAP.                            *
    *                          APAR PM33414                        *
    *                      04. Abend S0C4 when processing          *
    *                          truncated COBOL SYSDEBUG side file. *
    *                          APAR PM33415                        *
    *                      05. Abend S0C2 in module IDIXCEE entry  *
    *                          point JOBINFO at offset X'476'.     *
    *                          APAR PM33401                        *
    *                      06. CFA transaction cannot be executed  *
    *                          during CICS shutdown due to         *
    *                          SHUTDOWN(DISABLE) setting.          *
    *                          APAR PM28357                        *
    *                      07. Fault Analyzer receives abend AZTS  *
    *                          while processing application abend  *
    *                          AD2W.                               *
    *                          APAR PM33416                        *
    *                      08. Source line not reported when using *
    *                          ISPF packed Enterprise PL/I         *
    *                          compiler listing.                   *
    *                          APAR PM33417                        *
    *                      09. Abend S0C4 at entry point           *
    *                          FormatXMLData offset X'4CE'.        *
    *                          APAR PM33592                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    01. The potential existed for two Fault Analyzer tasks to wait
        on the same ECB, and hence only one would be posted out of
        the wait.
    02. A check for XFACILIT ALTER access was incorrectly being
        made.
    03. Fault Analyzer was being invoked in a POSIX(ON) LE
        environment.
    04. Freed storage pointers not reset causing subsequent free
        to abend S0C4.
    05. In a Websphere Application Server Control Region running
        storage protect KEY 2, if IBM Fault Analyzer has not been
        excluded from the region and an abend occurs causing Fault
        Analyzer to be called, it will get S0C2 trying to set KEY 8
        execution mode from its IDIXCEE invocation exit.
    06. CICS default setting for SHUTDOWN status was being used.
    07. Fault Analyzer is attempting to capture the 3270 terminal
        buffer, but the MRO connection is no longer active, so Fault
        Analyzer suffers a Terminal Control abend.
    08. The 'back-end' sections of an EPLI compiler listing require
        right-shifting since the ASA character '1' is not present.
        The right-shifting is not performed when using an
        ISPF-packed compiler listing.
    09. The buffer was too small to handle large amounts of XML
        data.
    

Problem conclusion

  • 01. The dual ECB usage has been modified.
    02. The check for XFACILIT ALTER access has been eliminated
        as part of the fault entry refresh processing.
    03. POSIX(OFF) has been added to the Fault Analyzer invocation.
    04. Freed storage pointers now reset.
    05. Code has been added to detect the call in KEY 2 and abort
        the analysis with message IDI0123S.
    06. SHUTDOWN(ENABLED) has been added to the CFA transaction
        definition.
    07. Fault Analyzer has been changed to suppress the 3270 buffer
        capture if the CICS connection has suffered an AD2W abend.
    08. The right-shifting is now performed when using an
        ISPF-packed EPLI compiler listing.
    09. Made buffer large enough to handle large XML data.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM27330

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655V5100

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-11-24

  • Closed date

    2011-02-28

  • Last modified date

    2011-04-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK65177

Modules/Macros

  • CDAEDPIE CDAEEDE  CDISDTFJ CDISJL   CDISWRAP
    EQALANGX GDIM04   GDIM08   GDIM10   GDIPHI06 GDIPHI07 GDIPH1
    
    ***This field was truncated.  To obtain the full apar record, please contact your local support center.***
    

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655V5100

Applicable component levels

  • RA10 PSY UK65177

       UP11/03/04 P F103

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
04 April 2011