IBM Support

PM18371: BASE64BINARY SET IN ANYSIMPLETYPE DOES NOT SERIALIZE CORRECTLY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • base64Binary set in anySimpleType does not serialize correctly
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users of IBM WebSphere Application Server   *
    *                  v7 Feature Pack for Service Component       *
    *                  Architecture (SCA) Refresh Pack v1.0.1 and  *
    *                  WebSphere Process Server v7.0               *
    ****************************************************************
    * PROBLEM DESCRIPTION: base64Binary value does not serialize   *
    *                      correctly                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If a base64Binary value is set using a wrapper and the data
    object is later saved to XML, the lexical value will be
    serialized in the hexBinary format, causing problems when
    later trying to load the saved XML.
    

Problem conclusion

  • base64Binary values are now correctly serialized using the
    base64Binary lexical format.
    
    APAR PM18371 is currently targeted for inclusion in Service
    Level (Fix Pack) 1.0.1.7 of WebSphere Application Server v7
    Feature Pack for Service Component Architecture (SCA) Refresh
    Pack. Please refer to the Recommended Updates page for
    delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM18371

  • Reported component name

    WAS SCA FEATURE

  • Reported component ID

    5724J0854

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-13

  • Closed date

    2010-07-21

  • Last modified date

    2010-07-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WAS SCA FEATURE

  • Fixed component ID

    5724J0854

Applicable component levels

  • R700 PSY

       UP