PK99788: CEMT S FILE(S*) ENA IS ISSUED AND GETS AN 'ERROR' MESSAGE. ONLY HAPPENS WHEN UK49670IS ON 09/11/16 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After applying CICS TS 3.2 PUT0906 All HIPERS & RSU thru 0909, a
    problem occurs when trying to enable a file. After issuing the
    Cemt command: CEMT S FILE(S*) ENA  , there is an error:
    Fil(S*      )
    ERROR. There are no other error messages, abends, or anything.
    Just the 'ERROR' indicating that there is an issue with trying
    to set (S*) ENABLED. The interesting thing here is that the
    problem only occurs when
    UK49670 is applied. Customer ran the CEMT S FILE(S*) ENA with
    the PTF applied and with it removed, and the 'ERROR' problem
    only occurs when the PTF is applied. So, in essence, the error
    that is encountered is the 'ERROR' message being displayed when
    it should not be.
    Additional Keywords: ERROR , FILE , 0909 , UK49670
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users with PTF UK49670 applied.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Attempts to execute CEMT SET xxx yyy,   *
    *                      where xxx is an option type and yyy     *
    *                      is some appropriate command for that    *
    *                      type, results in a phantom error        *
    *                      message line at the top of the results  *
    *                      returned.                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A command of the form
    
          CEMT S xxx(*) yyy
    
    is issued where xxx is an option type such as PROGRAM, FILE,
    PIPELINE,.... and yyy is some command. For instance for
    pipeline the following happens
    
    SET PI(*) ENA
    STATUS:  RESULTS - OVERTYPE TO MODIFY
     Pip(*       )                                        ERROR
    
    if the cursor is placed over the ERROR and enter is pressed,
    the result  of looking at the error is NOT FOUND.
    
    This problem only arises after PTF UK49670 has been applied.
    
    Additional Keywords. CEMT SET UK49670
    

Problem conclusion

  • UK49670
    DFHEMT56 has been amended to remove the phantom error message
    notification that appears as part of the real results after a
    call to CEMT SET xxx yyy, where xxx is an option type and yyy
    is some appropriate command for that type.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK99788

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-10-28

  • Closed date

    2009-11-30

  • Last modified date

    2010-01-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PM00336 UK52428

Modules/Macros

  •    DFHEIN56 DFHEMT56
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R500 PSY UK52428

       UP09/12/05 P F912

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]