Fixes are available
APAR status
Closed as program error.
Error description
When setting maxInactiveInterval to a high value appropriate for use in HTTP session replication, the high value (such as 1800) is able to be set correctly on the grid server with the primary shard, but on the replica shards it is fixed to 8 no matter how it is set. This results in very quick timeouts if there is a problem with the primary server.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere eXtreme Scale * * who are using ObjectGrid * * for HTTP session replication * **************************************************************** * PROBLEM DESCRIPTION: Sessions time out prematurely when the * * primary container server fails over * * to a replica. * **************************************************************** * RECOMMENDATION: * **************************************************************** Session timeout information was being transmitted incorrectly from primary to replica.
Problem conclusion
The fix is included in WebSphere eXtreme Scale Version 6.1.0.5 Cumulative Fix 3. A future cumulative fix will correct the problem for WebSphere eXtreme Scale Version 7.0. Refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=3023&uid=swg27005709
Temporary fix
Comments
APAR Information
APAR number
PK91001
Reported component name
XD EXTREME SCAL
Reported component ID
5724J3402
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-07-09
Closed date
2009-08-17
Last modified date
2009-08-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
XD EXTREME SCAL
Fixed component ID
5724J3402
Applicable component levels
R610 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSTVLU","label":"WebSphere eXtreme Scale"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
23 September 2020