Fixes are available
APAR status
Closed as program error.
Error description
Syndication is not completing and taking long time
Local fix
Problem summary
Syndication not completing or taking an excessive amount of time to complete
Problem conclusion
Cumulative fix 12 included changes related to Large File handling (PK81405) this changed the way that WCM transferred during syndication. This fix introduced a situation where syndication can get stuck in a loop trying to delete files from the subscribers temp directory. Thus syndication will either not complete or will complete once the file is released however in some cases this can take several hours. Syndication Traces will show a gap between: ******************* End of subscription update report ******************* and either: Syndication completed with errors for . . . or Syndication succeeded for . . . In addition this issue can result in higher CPU utilization than is normally associated with syndication because of the loop.
Temporary fix
Comments
APAR Information
APAR number
PK85213
Reported component name
LOTUS WEB CONT
Reported component ID
5724I2900
Reported release
60H
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-23
Closed date
2009-05-04
Last modified date
2009-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
WCM
Fix information
Fixed component name
LOTUS WEB CONT
Fixed component ID
5724I2900
Applicable component levels
R60H PSY
UP
R60J PSY
UP
R61A PSY
UP