A fix is available
APAR status
Closed as program error.
Error description
ASMA080E Statement is unresolvable after applying fix for PK77171. In addition, the following error may be issued after PTF's for PK77171 are applied: IEW2353E 243F SECTION QQUAD CONTAINS INVALID DATA. ERROR CODE IS 25000E. IEW2307E 1113 CURRENT INPUT MODULE NOT INCLUDED BECAUSE OF INVALID DATA. The second error is issued on the following sample code. QQUAD CSECT QQUAD AMODE 31 QQUAD RMODE 24 MYQQ DC Q(QWHERE) QWHERE DSECT DC F'0' END
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users. * **************************************************************** * PROBLEM DESCRIPTION: 1. * * After the apply of PTF for APAR PK77171 * * the error message ASMA080E may be * * issued incorrectly. Typically this will * * be for QCONS which are converted to an * * external section (DXD). * * 2. * * After a successful assembly it is * * possible to get the following error * * message from the z/OS Binder : * * IEW2353E 243F SECTION xxxxx CONTAINS * * INVALID DATA. ERROR CODE IS 25000E * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** 1. The error message ASMA080E may be generated incorrectly. 2. After a successful assembly it is possible to get the Binder error: "IEW2353E 243F SECTION xxxxx CONTAINS INVALID DATA. ERROR CODE IS 25000E."
Problem conclusion
The High Level Assembler has been modified to correct the problem causing error message ASMA080E and the Binder error.
Temporary fix
APAR Fixtest for PK84776.
Comments
APAR Information
APAR number
PK84776
Reported component name
HLASM MVS, VM &
Reported component ID
569623400
Reported release
160
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-04-15
Closed date
2009-06-02
Last modified date
2010-03-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
106PC1 UK47102 106PC1 UK47103 106PC1 UK47104 106PC1 106PC1
106PC1 106PC1 106PC1
Modules/Macros
ASMADOPD ASMAINFO ASMA00 ASMA1A ASMA1G ASMA1K ASMA1P ASMA1S ASMA1U ASMA13 ASMA2R ASMA22 ASMA24 ASMA26 ASMA5UNI ASMA9Z ASMA92 OPGEN
Fix information
Fixed component name
HLASM MVS, VM &
Fixed component ID
569623400
Applicable component levels
R160 PSY UK47103
UP09/06/03 P F906 Ø
R360 PSY UK47102
UP09/06/02 P 0906 Ø
R689 PSY UK47104
UP09/06/02 P E422 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSENW6","label":"High Level Assembler and Toolkit Feature"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160","Edition":"","Line of Business":{"code":"","label":""}}]