A fix is available
APAR status
Closed as program error.
Error description
The following problems are addressed in this APAR: 1. CHANGE.DB ICOFF is issued for recoverable index and not for nonrecoverable index. 2. IIUB029E IDCAMS PROCESSING FAILED is issued erroneously. This occurs for HALDB when DBRC=Y is specified in the INPUT statement and APAR PK73601 is applied. 3. COMPLETION CODE=A30 DUPLICATE KEY ENCOUNTERED occurs when SUBSEQ=(/CKxxxxx) is defined in the secondary index and APAR PK73601 is applied. 4. COMPLETION CODE=A09 INDEX BUILD PHASE 0 FAILURE occurs when SORTFSZ is specified. This is a task synchronization issue. 5. ABENDS13E in the main address space after secondary index load processing. This is a task synchronization issue and occurs when APAR PK73601 is applied.
Local fix
For Problem 1: "CHANGE.DBDS ICOFF" can be issued manually after IB completes. If the user issues "CHANGE.DB NONRECOV NOICREQ" to each nonrecoverable database in advance, the IC NEEDED flag is not turned on even if IB or other reorganization utility issues "NOTIFY.REORG".
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Index Builder for z/OS, * * Version 3 Release 1 (FMID=H22O310) * **************************************************************** * PROBLEM DESCRIPTION: This APAR fixes the following problems: * * 1. CHANGE.DB ICOFF is issued for * * recoverable index. * * 2. IIUB029E IDCAMS PROCESSING FAILED * * is issued erroneously. * * 3. COMPLETION CODE=A30 DUPLICATE KEY * * ENCOUNTERED occurs when * * SUBSEQ=(/CKxxxxx) is defined. * * 4. COMPLETION CODE=A09 INDEX BUILD * * PHASE 0 FAILURE occurs when SORTFSZ * * is specified. * * 5. ABENDS13E in the main address space * * after secondary index load * * processing. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR fixes the following problems: 1. NOTIFY.UIC and CHANGE.DBDS ICOFF are issued for recoverable index. 2. IIUB029E IDCAMS PROCESSING FAILED is issued erroneously. This occurs for HALDB when DBRC=Y is specified in the INPUT statement and APAR PK73601 is applied. 3. COMPLETION CODE=A30 DUPLICATE KEY ENCOUNTERED occurs when SUBSEQ=(/CKxxxxx) is defined in the secondary index and APAR PK73601 is applied. 4. COMPLETION CODE=A09 INDEX BUILD PHASE 0 FAILURE occurs when SORTFSZ is specified. This is a task synchronization issue. 5. ABENDS13E in the main address space after secondary index load processing. This is a task synchronization issue and occurs when APAR PK73601 is applied.
Problem conclusion
This APAR addresses the five problems listed in the Problem Summary field. To fix the problems, some of the current behaviors of Index Builder have been adjusted by this APAR. After applying this APAR, 1. The following DBRC commands are not issued automatically. - NOTIFY.UIC - CHANGE.DBDS ICOFF NOTE: To prevent the IC NEEDED flag from turning on for a nonrecoverable index, users should issue the DBRC command in advance : "CHANGE.DB DBD(name) NONRECOV NOICREQ". 2. VSAM REUSE|NOREUSE attribute is not altered by Index Builder. The VSAM data set to be loaded should be empty or reusable. If not, Index Builder returns an error without loading to it. IIUB053E DATA SET IDCAMS PROCESSING FAILED IIUB029E IDCAMS PROCESSING FAILED FOR DBD=dbdname. INDEX DATA SET(S) MAY BE NOT EMPTY AND NOT REUSABLE. 3. Runtime optimization code ( race code ) introduced by APAR PK73601 is deactivated to avoid errors added by the enhancement. 4. ULU and DLI of the IMS Batch regions are attached independently of the DBRC option of the INPUT statement.
Temporary fix
Comments
ž**** PE09/07/21 FIX IN ERROR. SEE APAR PK89037 FOR DESCRIPTION
APAR Information
APAR number
PK82341
Reported component name
IMS INDEX BUILD
Reported component ID
5655E2400
Reported release
310
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-11
Closed date
2009-03-30
Last modified date
2009-07-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK45334
Modules/Macros
IIUBIDCM IIUBINIT IIUDRVRX IIUDSRTD IIUIFS2 IIUIFS2A IIUIFS2B IIUIFS29 IIUIFS3 IIUIFS3A IIUIFS3B IIUIFS39 IIUNDXRC IIUPDBRC IIUSCA01 IIUSCA11 IIUSIN12 IIUTMRXT
| SC18910100 |
Fix information
Fixed component name
IMS INDEX BUILD
Fixed component ID
5655E2400
Applicable component levels
R310 PSY UK45334
UP09/03/31 P F903
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.