A fix is available
APAR status
Closed as new function.
Error description
TCP/IP FULL SERVER SUPPORT FOR SIMPLE TCP/IP ( STCP ) SIMULATIONS PROVIDES A MEANS FOR SIMULATING SERVERS SUPPORTING MULTIPLE CLIENT SOCKET CONNECTIONS IN PARALLEL. THE TPNS TCP/IP FULL SERVER SUPPORT IS ENABLED WHEN A DEV WITH TYPE=STCP AND STCPROLE=SERVER ARE CODED AND NEW OPERANDS BACKLOG=N OR MAXCLNTS=N IS ALSO CODED WITH AN 'N' VALUE GREATER THAN ONE. SAMPLE DATA SET MEMBER TCPFSDOC DOCUMENTS THIS NEW SUPPORT. ALSO, INFORMATION MESSAGE ITP433I CAN NOW BE INHIBITED.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Workload Simulator (WSim) * * Version 1 Release 1 * **************************************************************** * PROBLEM DESCRIPTION: WSim TCP/IP Full Server Support * **************************************************************** * RECOMMENDATION: * **************************************************************** TCP/IP Full Server Support for Simple TCP/IP ( STCP ) simulations provides a means for simulating servers supporting multiple client socket connections in parallel. The TPNS TCP/IP Full Server support is enabled when a DEV with TYPE=STCP and STCPROLE=SERVER are coded and new operands BACKLOG=n or MAXCLNTS=n is also coded with an 'n' value greater than one. Sample data set member TCPFSDOC documents this new support. Also, information message ITP433I can now be inhibited. +-------------------------------------------------------------+ + Please check our Communications Server for OS/390 homepages + + for common networking tips and fixes. The URL for these + + homepages can be found in Informational APAR II11334. + +-------------------------------------------------------------+
Problem conclusion
Temporary fix
Comments
BACKLOG=1-32767 (1 default) and MAXCLNTS=1-1999 (1 default) operands added. If BACKLOG=n or MAXCLNTS=n value greater than one, enable TCP/IP Full Server support for DEV TYPE=STCP,STCPROLE=SERVER. LISTEN() on LOCLPORT=n port number and ACCEPT() socket connections up to MAXCLNTS=n value in parallel. Allow ITP433I to be inhibited.
APAR Information
APAR number
PK81905
Reported component name
IBM WORKLOAD SI
Reported component ID
5655I3900
Reported release
110
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-03-05
Closed date
2009-03-09
Last modified date
2009-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK44686
Modules/Macros
ITP#FS ITPASCAN ITPDATE ITPDMDAT ITPDMOPC ITPDMTRC ITPDPQRY ITPDVQRY ITPGENIM ITPGENTX ITPGSTAT ITPKSSNU ITPLVVAL ITPMLBLD ITPNTSLN ITPNTSTD ITPNTWRK ITPOPCLS ITPOPT ITPOPTBL ITPPRINT ITPQRESP ITPQRYCS ITPQRYSA ITPREPRT ITPRESET ITPRSPCK ITPSSFTN ITPSSFUN ITPSTSND ITPTLDEV ITPTLEXC ITPTLSCH ITPUSRIN ITPWTINF ITPWTMSG
Fix information
Fixed component name
IBM WORKLOAD SI
Fixed component ID
5655I3900
Applicable component levels
R110 PSY UK44686
UP09/03/10 P F903
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSL28L","label":"Workload Simulator for z\/OS and OS\/390"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]