IBM Support

PK72088: DFSUOLC PROC GENERATED INCORRECTLY AFTER PK37127 08/09/24 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After application of PK37127 (UK39556), DFSUOLC procedure
    is generated incorrectly. &VERS was put over 72 column as next
    example.
                                                        col72
                                                          |
                                                          V
    //       PROC FUNC=INI,ACBS=,......,VERS=,SOUT=A       00000010
    //STEP1  EXEC PGM=DFSUOLC0,P.......FMTS,&MDID,&PLEX,&VE00000020
    //STEPLIB  DD DSN=IMS10A.&SY.......                    00000030
    .....
    This is an error in GENPROCS macro at SEQ#01963700-01963800.
    .
    We tested DFSUOLC0 by specify VERS keyword manually.
    But it was rejected with next messages.
     BPE0003E AN ERROR OCCURRED PARSING DFSUOLC0 INPUT PARAMETERS
     BPE0003E AT CHARACTER 11
     BPE0003E FAILING TEXT: "0,,             "
     BPE0003E NUMERIC VALUE OUTSIDE OF LEGAL RANGE
    This error was detected if we specify MDID=0.
    MDID=0 had been worked before application of PK37127.
    This is because DFSUOLC0 SEQ#22672000 has incorrect RANGE
    specification.
                   REQUIRED=NO,RANGE=(1,99999999)
    Valid range must be (0,99999999).
    Also, DFSUOLC0 has a code to reject MDID=0 at SEQ#06500000.
    DFSUOLC0 should accept MDID=0.
    System Utilities Reference manual has next statement for MDID.
      This should be initialized to zero to indicate that the
      number of global online changes performed is zero.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS V10 users of the DFSUOLC0 utility.   *
    ****************************************************************
    * PROBLEM DESCRIPTION: After APAR PK37127, the DFSUOLC0        *
    *                      utility cannot be used to initialize    *
    *                      the OLCSTAT with MODID=0.               *
    *                                                              *
    *                      The sample DFSUOLC0 proc shipped        *
    *                      in GENPROCS is not usable.              *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    After APAR PK37127, the DFSUOLC0 utility fails with the
    following message when MDID=0 is specified:
     BPE0003E AN ERROR OCCURRED PARSING DFSUOLC0 INPUT PARAMETERS
     BPE0003E AT CHARACTER 11
     BPE0003E FAILING TEXT: "0,,             "
     BPE0003E NUMERIC VALUE OUTSIDE OF LEGAL RANGE
    MDID=0 is valid to be specified to initialize the OLCSTAT.
    
    The sample DFSUOLC0 proc shipped in GENPROCS generates
    sample JCL that is not usable. The &&VERS is generated in
    column 72.
    

Problem conclusion

  • AIDS: RIDS/DCS RIDS/CMD DCS CMD
     GEN: PCSS/CTL CTL
    KEYWORDS:
    
    *** END IMS KEYWORDS ***
    Logic is modified in DFSUOLC0 to accept MDID=0.
    
    GENPROCS is modified to generate the PARM= on
    a separate line so the generated JCL is usable.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK72088

  • Reported component name

    IMS V10

  • Reported component ID

    5635A0100

  • Reported release

    010

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-09-16

  • Closed date

    2008-10-16

  • Last modified date

    2009-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK40770

Modules/Macros

  • DFSUOLC0 GENPROCS
    

Fix information

  • Fixed component name

    IMS V10

  • Fixed component ID

    5635A0100

Applicable component levels

  • R010 PSY UK40770

       UP08/10/24 P F810 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCVRBJ","label":"System Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 May 2009