APAR status
Closed as program error.
Error description
Online Pointer Checker abends with ABENDS0C1 when FULLSTEP=YES and TYPRUN=RPT are specified, or FULLSTEP=YES is specified and TYPRUN is not specified, after PK67974/UK38383 has been installed. S0C1
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Online Pointer Checker users and Online * * Expert Reorganization users of High * * Performance Fast Path Utilities FP Online * * Tools Version 3 Release 2 (FMID: H31A320). * **************************************************************** * PROBLEM DESCRIPTION: Online Pointer Checker got ABEND 0C1 * * when FULLSTEP=YES and TYPRUN=RPT are * * specified, or FULLSTEP=YES is * * specified and TYPRUN is not specified. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** Online Pointer Checker called a new module that was added by the APAR PK67974. But the module was not loaded and OPC got ABEND 0C1.
Problem conclusion
HFPQMLO0 has been modified to load ITKB processing modules. This problem is due to a change made by APAR PK67974, its PTF UK38383 has been marked PE. 320Y HFPQMLO0
Temporary fix
Comments
APAR Information
APAR number
PK69773
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
320
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-07-29
Closed date
2008-07-30
Last modified date
2008-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HFPQMLO0
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R320 PSY UK38513
UP08/08/04 P F808 Ø