PK67141: FIELD VALIDATION MARKS WRONG TAB

 

APAR status

  • Closed as program error.

Error description

  • When creating a content using authoring template on the
    following conditions;
    -Use Tab
    -Add extra required field(s)
    'Content' tag is always marked with [x] simbol if any extra
    field is not filled out.
    

Local fix

Problem summary

  • When creating a content using authoring template on the
    following conditions;
    -Use Tab
    -Add extra required field(s)
    'Content' tag is always marked with [x] simbol if any extra
    field is not filled out. To put error mark on a tab including
    control(s) with inappropriate
    inputs, AuthoringUI needs to validate each control. These
    validation is
    done on two stages, with first one checking if default mandately
    fields
    on controls are filled out correctly, then with second one
    seeing if
    required fields specified by AuthoringTemplate also inputed
    well.
    However, currently, indicators are shown based only on the
    results of
    the first validation. Plus, if the # of validation errors
    detected on
    the second stage is larger than ones found on the first stage
    are all
    treated as errors related to Content tab. Thus, tab notification
    goes
    wrong once AT specifies extra required fields.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PK67141

  • Reported component name

    LOTUS WEB CONT

  • Reported component ID

    5724I2900

  • Reported release

    60F

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-06-05

  • Closed date

    2008-06-05

  • Last modified date

    2008-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    LOTUS WEB CONT

  • Fixed component ID

    5724I2900

Applicable component levels

  • R60G PSY

       UP

[{"Business Unit":{"code":"BU051","label":"N\/A"},"Product":{"code":"SUPPORT","label":"IBM Web Content Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1.2","Line of Business":{"code":"LOB33","label":"N\/A"}}]

Document Information

Modified date:
21 December 2021