A fix is available
APAR status
Closed as program error.
Error description
ASMA973U WORK FILE MAXIMUM BLOCK COUNT EXCEEDED is one error that could be seen when assembling TPF or a very large program. This is one problem I have found, however when a beta fix was applied, the existing TPF assembly still runs out of storage. The option WORKFILE is used with a large //SYSUT1 DD SPACE and a large REGION option on the job statement.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users using the WORKFILE option. * * * **************************************************************** * PROBLEM DESCRIPTION: When using the WORKFILE option HLASM * * is not using the correct BLKSIZE for * * the WORKFILE and is trying to put all * * internal blocks in storage. * * * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * * * **************************************************************** When using the WORKFILE option HLASM is not using the correct BLKSIZE for the WORKFILE and is trying to put all internal blocks in storage.
Problem conclusion
The High Level Assembler has been modified to ensure that the WORKFILE is used when required and that the correct BLKSIZE is used.
Temporary fix
Comments
APAR Information
APAR number
PK62855
Reported component name
HLASM MVS, VM &
Reported component ID
569623400
Reported release
150
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-03-17
Closed date
2008-06-03
Last modified date
2008-12-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK37046 UK37048 UK37047
Modules/Macros
ASMAINFO ASMA00 ASMA9Z
Fix information
Fixed component name
HLASM MVS, VM &
Fixed component ID
569623400
Applicable component levels
R150 PSY UK37047
UP08/06/05 P F806
R350 PSY UK37046
UP08/06/04 P 0806
R589 PSY UK37048
UP08/06/04 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"150","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSENW6","label":"High Level Assembler and Toolkit Feature"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"150","Edition":"","Line of Business":{"code":"","label":""}}]