Error description

  • Recreatable scenario:
    Agent fails to reconnect to D5API (OMPE Server)
    for the first issue:
    Bring up ompe server
    - bring up agent
    - agent connects to D5API and all ok
    - stop ompe server
    - restart ompe server
    - agent fails to reconnect to D5API
    Messages from Agent JESYSMSG
    KO2I0205U UNABLE TO LOCATE COMMON COLLECTOR REGISTRY ENTRY FOR
    OM SERVER SDF1OMP
    KO2I0212U UNABLE TO LOCATE A CONNECTION TO DB2=SN13 IN OM SERVER
    SDF1OMPE - DISC
    Messages from Agent RKLVLOG:
    api_connect") KO2I1002E Connection to OMPE Server SDF1OMPE
    Failed Subsystem D83
    10 Not Retrying
    S1_GetEnv") KDP_D2_STC="SDF1OMPE"
    S1_GetEnv") KDP_D2_STC="SDF1OMPE"
    api_connect") Problem with connect DB2 D831 rc 16 DAPIRTNC 16
    api_connect") Setting OMPE error D831
    api_connect") KO2I1002E Connection to OMPE Server SDF1OMPE
    Failed Subsystem D831
    10 Not Retrying
    S1_GetEnv") KDP_D2_STC="SDF1OMPE"
    api_collect") KO2I1001W Connection to OMPE Server SDF1OMPE Lost
    Return=00000034
    =00000014
    api_collect") KO2I1001W Connection to OMPE Server SDF1OMPE Lost
    Return=00000034
    =00000014
    
    
    Please apply UK35126 for APAR PK63563 when this PTF is applied
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - Tivoli Enterprise Monitoring Agent         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Agent unable to reconnect to            *
    *                      server/collector, especially after the  *
    *                      server/collector is recycled. Active    *
    *                      DB2 systems are not showing active in   *
    *                      TEP, especially after being recycled.   *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Reason and return codes returned from the server
    were not properly interpreted by the agent.
    
    PROBLEM CONCLUSION:
    Interpret reason and return codes such that connection
    retries are appropriately allowed.
    
    KEYWORDS: KO2I0212U KO2I1002E KO2I1001W
    

Problem conclusion

  • PROBLEM CONCLUSION:
    Interpret reason and return codes such that connection
    retries are appropriately allowed.
    
    KEYWORDS: KO2I0212U KO2I1002E KO2I1001W
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PK60525

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-02-05

  • Closed date

    2008-03-20

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK34762

Modules/Macros

  •    KD5AGENT KD5ATC00 KD5AUTO1 KD5CMD00 KO2ACONB
    KO2AINIB KO2AOMBB KO2APCAA KO2APCAS KO2APCA2 KO2APCBA KO2APCBS
    KO2APCB2 KO2APCCA KO2APCCS KO2APCC2 KO2APC1A KO2APC1S KO2APC12
    KO2APC2A KO2APC2S KO2APC22 KO2APC3A KO2APC3S KO2APC32 KO2APC4A
    KO2APC4S KO2APC42 KO2APC5A KO2APC5S KO2APC52 KO2APC9A KO2APC9S
    KO2APC92
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK34762

       UP08/03/22 P F803 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410"}]

Document Information

Modified date: