Error description

  • ASRA at EYU0PMDI+05C2.  Label aligned on doubleword boundary
    instead of halfword inserted six bytes of binary zeros in
    executable code.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 users with PK46095    *
    *                 (UK26923) applied.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION:    After applying PTF UK26923, you see  *
    *                      the following problems:                 *
    *                      - When installing RTA/MRM STATDEFs, you *
    *                        receive Abend ASRA (S0C1) at offset   *
    *                        +05C2 in module EYU0PMDI (PMDI - RTA  *
    *                        Install MRM Definition).              *
    *                      - When shutting down a MAS for which    *
    *                        RTA/MRM definitions were installed,   *
    *                        you receive the following message in  *
    *                        the CMAS job log:                     *
    *                                                            . *
    *                           EYUPM0106E  RTA Specification      *
    *                              (SpecName) unsuccessfully       *
    *                              released for Context(CICSplex)  *
    *                              Scope(CICSsys).                 *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes must be recycled to pick    *
    *                 up the new code.  Note that the restarts     *
    *                 do not need to be done at the same time.     *
    ****************************************************************
       A coding error caused insertion of six bytes of binary zeros
    at +05C0 in module EYU0PMDI.
       During MAS termination, module EYU0PMDD (PMDD - Discard RTA
    MRM Definitions) may attempt to remove an element from the
    Installed RTADEF list after that list has been deleted.  The
    resulting exception causes the message to be issued, and pre-
    vents later definitions from being deactivated properly.
    

Problem conclusion

  •    Modules EYU0PMDI and EYU0PMDD have been modified to correct
    the errors which caused the above problems.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

  •    After applying PTF UK26923, you see
    the following problems:
    - When installing RTA/MRM STATDEFs, you
      receive Abend ASRA (S0C1) at offset
      +05C2 in module EYU0PMDI (PMDI - RTA
      Install MRM Definition).
    - When shutting down a MAS for which
      RTA/MRM definitions were installed,
      you receive the following message in
      the CMAS job log:
                                          .
         EYUPM0106E  RTA Specification
            (SpecName) unsuccessfully
            released for Context(CICSplex)
            Scope(CICSsys).
    
    
       A coding error caused insertion of six bytes of binary zeros
    at +05C0 in module EYU0PMDI.
       During MAS termination, module EYU0PMDD (PMDD - Discard RTA
    MRM Definitions) may attempt to remove an element from the
    Installed RTADEF list after that list has been deleted.  The
    resulting exception causes the message to be issued, and pre-
    vents later definitions from being deactivated properly.
    
    
       Modules EYU0PMDI and EYU0PMDD have been modified to correct
    the errors which caused the above problems.
    

APAR Information

  • APAR number

    PK49787

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-07-26

  • Closed date

    2007-08-03

  • Last modified date

    2007-09-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK27837

Modules/Macros

  •    EYU0PMDD EYU0PMDI
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK27837

       UP07/08/08 P F708

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
04 September 2007